Step 1: Prepare The Site For Acx5448 Installation; Rack Requirements For An Acx5448 Router - Juniper ACX5448 Quick Start Manual

Universal metro router
Hide thumbs Also See for ACX5448:
Table of Contents

Advertisement

CAUTION:
Before removing or installing components, attach an ESD strap to an ESD point, and attach the other end
of the strap to your bare wrist. Failure to use an ESD strap can result in damage to the hardware components.
WARNING:
This Quick Start contains a summary of safety warnings in
list of warnings for this router, including translations, see the ACX5448 Universal Metro Router Hardware Guide.
Figure 4: ESD Point on the ACX5448 Router
1
1— ESD point

Step 1: Prepare the Site for ACX5448 Installation

Rack Requirements for an ACX5448 Router on page 3
Router Clearance Requirements on page 4
Router Cooling and Airflow Requirements on page 5
Tools Required to Prepare the ACX5448 Router for Installation on page 6

Rack Requirements for an ACX5448 Router

ACX5448 routers are designed to be installed on four-post racks.
Table 1
provides the rack requirements and specifications for an ACX5448 router.
Table 1: Rack Requirements for an ACX5448 Router
Rack Requirement
Guidelines
Rack type
Use a four-post rack that provides bracket holes or hole patterns spaced at 1–U increments (1.75 in.
or 4.45 cm) and that the rack meets the size and strength requirements to support the weight.
A U is the standard rack unit defined in Cabinets, Racks, Panels, and Associated Equipment (document
number EIA-310–D) published by the Electronics Industry Association.
Mounting bracket hole
Ensure that the holes in the mounting brackets are spaced at 1 U (1.75 in. or 4.45 cm) so that the router
spacing
can be mounted in any rack that provides holes spaced at that distance.
Copyright © 2018, Juniper Networks, Inc.
ACX5448 Universal Metro Router Quick Start Guide
"Safety Warnings" on page
17. For a complete
3