Installation: On/Off Remote Button
1
Decide on a suitable location for the ON/OFF button. Mark the centre position and
draw a vertical line using a spirit level to assist in the alignment of the ON/OFF button.
Using a suitable hole saw, drill a 29-30mm diameter hole to a minimum depth of 50mm.
Note: The ON/OFF button must be installed on a flat and even wall surface
avoiding any grout lines.
2
Route the cable from the digital valve through the hole in the wall.
Note: Make sure that you use appropriate cable conduit / trunking to facilitate
maintenance.
Using the cleaning wipe (supplied) clean the surface around the mounting hole.
Note: Do not remove the line at this stage.
24
29 - 30mm
3
Connect the cable to the back of the On/Off Remote Button and push the rubber
grommet into place.
The alignment of the On/Off Remote Button cannot be adjusted when it is fitted.
Make sure to test fitment before removing the tape. This will ensure that there is no
clearance issue.
4
Carefully remove the paper from the adhesive back.
Carefully, visually align the symbol to the vertical line on the wall. Locate into the hole
in the wall and push firmly. Clean off the vertical line once the On/Off Remote Button
is correctly installed. If required, the On/Off Remote Button can be removed from the
backplate by rotating anticlockwise.