Temperature override Button disable
The Mira 415 incorporates a safety feature which prevents the temperature
override button from being depressed, enabling the user to access a higher shower
temperature. The shower control is despatched from the factory with the button in
the "enabled" position. The following sequence will allow the installer to "disable"
the temperature override button if required.
1.
Ensure the shower control is turned off.
Remove the concealing cap.
2.
Locate the plastic temperature override stop.
3.
Pull out the temperature override stop and reposition it in the slot adjacent to
the red temperature override button.
4.
Reversing the above procedure will "enable" the temperature override button
movement.
36