Mira Mode Maxim Installation And User Manual page 25

Digital mixing valve
Table of Contents

Advertisement

Cleaning the CloudCore™ spray plate
1
Insert the spray plate removal tool into
the corresponding feature in the core
sprayplate.
2
Hold the deluge showerhead with
one hand and turn the removal tool
anticlockwise to unscrew the core
sprayplate from the showerhead.
Note: There may be some residual
water in core spray plate.
3
Clean the core spray plate silver mesh
with mild washing up detergent or soap
solution, rinse under water and wipe
using a soft cloth or brush.
4
Replace with alternative or cleaned
CloudCore™ or RainCore™ spray plate.
Inser t the spray plate tool into the
corresponding feature and turn clockwise
to tighten.
48
Replace/Clean the Check Valves/Filters
Read the section "Important Information" first.
Before replacing any parts ensure that the underlying cause of the malfunction has been
identified. If the Digital Mixing Valve is dismantled during installation or servicing then upon
completion the product must be inspected to ensure there are no leaks.
Warning! There are no user serviceable components beneath the cover of the appliance.
Only a competent tradesperson should remove the cover.
Checkvalve Cartridges and Filters - Removal and Installation
Hot water entering the cold supply, or vice versa, indicates that immediate attention is
necessary. This is carried out by removing and cleaning, or renewing as necessary, the
checkvalve cartridges.
Note: Ensure for HP Mixer Valve that flow regulator is refitted in hot supply, if previously
fitted.
Isolate the electrical and water supplies to
the Digital Mixer Valve, and open an outlet
fitting to release pressure and to assist the
draining of residual water. Unscrew the plastic
nuts and either withdraw the pipework or
remove Digital Mixing Valve to gain access
to the checkvalve cartridges and filters. Use
a flat blade screwdriver to carefully lever the
cartridges out. Remove the filters and clean
or renew. Refit seals, pipes and plastic nuts.
Plastic nuts require hand tightening only.
Restore water supply and electrical supply.
Test shower and check for leaks.
Disposal and Recycling
When this appliance has reached the end of its serviceable life, it should be disposed of in a
safe manner, in accordance with current local authority recycling, or waste disposal policy.
For more information about recycling, please contact your local council office.