Valve Installation Orientation
The Digital Mixing Valve (which contains the thermostatic mixing valve)may only be orientated
in the positions shown below. Failure to do so will compromise the ability of the unit to fail-safe
and deliver constant blend. If the power supply cable is damaged, it must be replaced by
the manufacturer or a service engineer.
Warning! Turn off the electrical and water supplies before proceeding with the installation
of the appliance. The electricity must be turned off at the mains and the appropriate
circuit fuse electrically isolated, if applicable. Caution! Risk of product damage. Do
not run Pumped Valve (low pressure version) without a water supply.
Inlets
Outlets
Mounting on a vertical surface
1. Isolate the electrical supply to Digital Mixing Valve.
2. Mark the fixing holes in the required positions. Drill and plug the fixing holes.
Note: Installers may wish to use alternative cavity fixings, when installing onto a dry
lined, stud partition, shower cubicle or laminated panel wall structures. However, these
methods of fixing are beyond the scope of this guide.
3. Secure the Digital Mixing Valve in position with the fixing screws (supplied).
Caution! Risk of product damage. Make sure both hot and cold supply pipes are flushed
thoroughly prior to connection to the Digital Mixing Valve. Any product malfunction
caused by pipework debris is not covered under the guarantee.
4. Connect the hot and cold water supply pipes to the Digital Mixing Valve.
20
Inlets
Outlets
Mounting on a horizontal surface
Push-fit Connector
to the Shower
Anti tamper plate may
differ from the one shown
5. Remove the anti-tamper plate and the rubber bung from the Digital Mixing Valve.
6. Connect the coupler cable to the valve. Make sure that it is connected correctly.
7. Fit the rubber bung over the cable and fit into the socket to seal the connection.
Note: The fittings of the anti-tamper plate may differ from the one illustrated. Make
sure that you install it in the correct orientation to suit your product.
8. Re-install the anti-tamper plate and lock in position with the screw.
9. Install the Controller and Shower Fittings. Refer to the appropriate section in this manual.
Wiring to Fused Spur Box.
Make sure that the fused
spur is easily accessible.
(see installation schematic)
Cold Inlet
Push-fit Isolators
fitted to both inlets
Hot Inlet
Coupler Cable
Rubber Bung
21