Installing the Transmitter continued
2.2.1
Environmental requirements
The transmitter's environmental requirements include temperature, humidity, and vibration.
Temperature limits
Install the transmitter in an environment where ambient temperature is between –40 and +140 °F
(–40 and +60 °C). If possible, install the transmitter in a location that will prevent direct exposure to
sunlight.
Different ambient temperature requirements may apply, depending on your installation. Refer to the
ATEX, IECEx, CSA, or UL installation manuals shipped with the transmitter or available on the
Micro Motion web site.
Humidity limits
Install the transmitter in an environment where relative humidity is between 5 and 95%, non-
condensing at 140 °F (60 °C).
Vibration limits
The transmitter meets IEC 68.2.6, endurance sweep, 5 to 2000 Hz, 50 sweep cycles at 1.0 g.
2.2.2
Hazardous area classifications
If you plan to mount the transmitter in a hazardous area:
•
Verify that the transmitter has the appropriate hazardous area approval. Each transmitter has a
hazardous area approval tag attached to the transmitter housing.
•
Ensure that any cable used between the transmitter and the sensor meets the hazardous area
requirements.
For more information about hazardous area classifications and requirements, see Section A.2.
2.2.3
Power source
Connect the transmitter to an AC or DC voltage source. The transmitter automatically recognizes the
source voltage.
AC power requirements
If you are using AC power, the following requirements apply:
•
85–265 VAC
•
50/60 Hz
•
6 watts typical, 11 watts maximum
Transmitter Installation: Model 1700 and 2700 Transmitters