1.3

Flowmeter components

The Model 1700 or 2700 transmitter is one component in your Micro Motion flowmeter. Other major
components include:
The sensor, which provides measurement functions
The core processor, which provides memory and processing functions
To install the transmitter, you must know your transmitter type and outputs option board. The
following section provides information on obtaining this information.
1.4

Transmitter type, installation type, and outputs option board

To install the transmitter, you must know your transmitter type, installation type, and outputs option
board. This section provides information on obtaining this information. The codes described below
match the codes that were used to order your transmitter.
1. Obtain the transmitter's model number, which is provided on a tag attached to the side of the
transmitter.
Model 1700 transmitters have a model number of the form
Model 2700 transmitters have a model number of the form
2. The fifth character in the model number (
that was ordered:
R = remote (4-wire remote installation)
I = integral (transmitter mounted on sensor)
C = transmitter/core processor assembly (9-wire remote installation)
B = remote core processor with remote transmitter
Note: For more information on installation type, see Figure 2-1.
3. The eighth character in the model number (
board.
A = transmitter with analog outputs option board (one mA, one frequency, one RS-485)
B = transmitter with configurable input/outputs option board, default output configuration
(two mA, one frequency)
C = transmitter with configurable input/outputs option board, customized output
configuration
D = transmitter with intrinsically safe outputs option board
Note: The remaining characters in the model number describe options that do not affect transmitter
installation.
2
Improper installation could cause measurement error
or flowmeter failure.
Follow all instructions to ensure transmitter will operate
correctly.
CAUTION
xxxxXxxxxxxxxx
xxxxxxxXxxxxxx
Transmitter Installation: Model 1700 and 2700 Transmitters
1700xxxxxxxxxx
2700xxxxxxxxxx
) represents the installation type
) represents the outputs option
.
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Micro motion 1700

Table of Contents