Kohler Industrial Generator Set Operation Manual page 113

10-1000 kw with apm402 controller; decision-makerr 3000 controller
Table of Contents

Advertisement

Description
Charger Temperature
Compensation Slope (mV/_C)
Charger Voltage Absorption
(V)
Charger Voltage Bulk (V)
Charger Voltage Equalize (V)
Note: Equalize is only
available with FLA/VRLA
topology selected.
Charger Voltage Float (V)
Current transformer ratio ]
ECM power
Engine cooldown delay
Engine (cyclic) crank on
Engine (cyclic) crank pause
Engine ECM start delay
Engine idle duration
Engine no. of (cyclic) crank
cycles
Engine restart delay
Engine start aid delay
Engine start delay
Equalize Current Limit (A)
Note: Equalize is only
available with FLA/VRLA
topology selected.
Forced Charge Cycle Reset
Output Enable
Voltage regulator gain
Voltage regulator stability
adjust
Voltage regulator, volts per
Hertz slope
Voltage regulator, volts per
Hertz cutin frequency
* Some functions require optional input sensors or are engine ECM dependent on some generator set models.
[ ECM inputs are engine manufacturer dependent.
] Changeable only by resetting the controller with a personality profile (SiteTech 1.4 or higher).
** Denotes the default parameter range. Typically, ranges for the NiCad battery topology are slightly wider. For more details, refer to the battery
charger operation manual.
ST--Short Term, LT--Long Term
TP-6694 7/18
Write
Access
Controller Display
Display
Message
SiteTech
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Reduced Out
S
S
S
S
S
GenSet
Mode
Always
Range
Default
Running
Setting
Selection
Stopped
--40 – 0
-30
(12 V)
(12 V)
A
-80 – 0
--60
(24 V)
(24 V)
13 – 15
14.25
(12 V)**
(12 V)
A
26 – 30
28.5
(24 V)**
(24 V)
13 – 15
14.25
(12 V)**
(12 V)
A
26 – 30
28.5
(24 V)**
(24 V)
14 – 16
(12 V)
A
28 – 32
(24 V)
13 – 14
13.25
(12 V)**
(12 V)
A
26 – 28
26.5
(24 V)**
(24 V)
S
1--
1200
S
0--1
0
A
A
A
A
A
S
1--6
3
A
A
A
A
1–5
Active
A
Inactive
Inactive
A
Fixed
Active
R
1--255
128
R
1--255
128
R
1--10
5
R
42--62
57.5
Time
Default
Programmer-
Delay
Time
Range
Delay
Defined
Settings
(sec.)
(sec.)
Adjustable with
Charger Custom
Profile enabled.
Adjustable with
Charger Custom
Profile enabled.
Adjustable with
Charger Custom
Profile enabled.
Adjustable with
Charger Custom
Profile enabled.
Adjustable with
Charger Custom
Profile enabled.
0--600
300
10--30
15
1--60
15
0--300
0
0--60
60
1--10
10
0--10
0
0--300
0
Adjustable with
Charger Custom
Profile enabled.
Appendix 113

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents