Needle Cooler; Adjusting The Position Of The Blow Pipe; Adjusting The Air Flow; Chain-Off Thread Cutter (Suction Of Thread Waste) - JUKI MS-1261A-DWS Instruction Manual

Table of Contents

Advertisement

3-15. Needle cooler

3-15-1. Adjusting the position of the blow pipe

3-15-2. Adjusting the air flow

3-16. Chain-off thread cutter (suction of thread waste)

To
To
decrease
increase
1) Loosen screw ❶ .
2) Adjust the position of blow pipe ❷ in terms of the
longitudinal direction and rotational direction.
3) Tighten screw ❶ to secure blow pipe ❷ .
Adjust the air flow of the needle cooler by turning
speed controller knob ❶ . Turn the speed controller
knob clockwise to decrease the air flow or counter-
clockwise to increase it.
Adjust the air flow of the needle cooler by turning
speed controller knob ❶ . Turn the speed controller
knob clockwise to decrease the air flow or counter-
clockwise to increase it.
– 18 –