Caution
When [Up fusing Initial Temp.] is changed, "fusing failure" (Toner is peeled off because
fusing temperature is not enough) may occur.
3. Decrease Upper Fusing Roller Temperature for respective trays.
[Machine]→ [Paper Setting]→ [Change Set]→ [Expert Adj.]→[Upper Fusing Roller
Temperature]
As the first step, change temperature by 10 °C then gradually decrease (Max 20 °C)
To avoid fusing under, print the test pattern 20 sheets of No. 69 and check image.
5.
If the effect is not enough, replace the fusing belt (A57V720200) to that for the
envelope fusing unit.