iv) Adjust the gaps between the paper and the side guides referring to the following steps 1
through 4.
Note:
•
Especially, to keep slight gap mentioned in 2 is important. Otherwise, JAM
(non suction, multi-feed, buckling) occurs.
Manual adjustments of side guides
1. Side guide scale: Set the side guides so that the front and rear indicates the same value.
* Read the value at the edge of the steel plate.
2. Gap between papers and guides: Keep 0.1 to 0.2mm at each side
3. Fix side guide: Rotate the knob to fix.
4. Check the paper can move smoothly: Slide the paper by hand and confirm that
it moves smoothly.
If it is caught, JAM may occur (see the figure in below)
Reference
3. Rotate the knob to
fix.
KONICA MINOLTA Confidential
Front
1. Set the side
guides. Be sure
that the steel plate
indicates the
same at front and
rear scales
- 150 -
Rear