Table 2 has the following columns:
● Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
● Setting
Select the setting from the drop-down list. You have the following options:
– Up
– Down
– "-" (disabled)
Procedure
Configure error monitoring for a port
1. From the relevant drop-down list, select the options of the slots / ports whose connection
status you want to monitor.
2. Click the "Set Values" button.
Configure error monitoring for all ports
1. Select the required setting from the drop-down list of the "Setting"column.
2. Click the "Copy to Table" button. The setting is adopted for all ports of table 2.
3. Click the "Set Values" button.
SCALANCE S615 Web Based Management
Configuration Manual, 05/2015, C79000-G8976-C388-02
Error handling is triggered when the port changes to the active status.
(From "Link down" to "Link up")
Error handling is triggered when the port changes to the inactive status.
(From "Link up" to "Link down")
The error handling is not triggered.
Configuring with Web Based Management
4.4 "System" menu
101