Steam generator auto-rinse,
deliming and manual draining
Auto-rinse
Your CombiMaster is equipped with an automatic
steam generator rinsing and draining function. This
feature significantly extends the period between
deliming intervals.
Deliming
Your CombiMaster must be delimed at regular inter-
vals depending on water hardness and the amount of
use. Deliming must only be done by a qualified Henny
Penny service technician. Contact your Henny Penny
distributor to discuss a deliming schedule.
Draining the steam generator
You should drain the steam generator before moving,
shipping, storing the unit, or to prevent freezing in
water lines.
1
Open cabinet door.
2
Select Cool Down mode
3
Press and hold probe temperature key for
10 seconds.
4
"CLEN" will appear in cabinet temperature display.
5
Select SC with temperature dial
CLEN
SC
6
Close water tap
7
Press Timer key once.
Leave mode dial at Cool Down position for at least 45
seconds. Steam generator will drain.