6-11. BLOWER REPLACEMENT

Aug. 2014
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move
the POWER switch to OFF and disconnect main
circuit breaker, or unplug cord at wall receptacle.
2. Remove the lower back shroud (See back shroud removal).
3. Using a phillips head screw, remove the two screws that
secures the blower to the flue. One screw is located on the
back side of the flue.
4. Cut zip ties that are holding the wires to the blower.
Remove the wire nuts from the wires.
5. Remove blower.
6. Reconnect new blower wires to the existing wires with wire
nuts.
7. Tighten the new blower onto the flue with the two screws.
8. Zip tie wires back to the blower.