1-4. ERROR CODES
DISPLAY
"E-4"
"E-5"
"E-6A"
"E-6B"
"E-10"
"E-15"
"E-18-A"
"E-18-B"
"E-18-C"
Aug. 2014
In the event of a control system failure, the digital display
shows an error message. The message codes are shown in the
DISPLAY column below. A constant tone is heard when an er-
ror code is displayed, and to silence this tone, press any button.
CAUSE
Control board
overheating
Oil overheating
Temperature probe
open
Temperature probe
shorted
Hight limit
Drain switch
LH level sensor open
RH level sensor open
Both sensors open
CORRECTION
Turn switch to OFF position, then turn switch back
to ON; if display shows "E-4", the control board is
getting too hot; check the louvers on each side of
the unit for obstructions
Turn switch to OFF position, then turn switch back
to ON; if display shows "E-5", the heating circuits
and temperature probe should be checked
Turn switch to OFF position, then turn switch back
to ON; if display shows "E-6A", the temperature
probe should be checked
Turn switch to OFF position, then turn switch back
to ON; if display shows "E-6B", the temperature
probe should be checked
Let unit cool down (15-20 minutes), push up on
metal reset button under right side of the controls;
if high limit does not reset, high limit must be
replaced
Make sure drain knob is completely pushed-in; if E-15
persists, have drain switch checked
Turn switch to OFF position, then turn switch back to
ON; if display still indicates a failed sensor, have the
connectors checked at the control board; have sensor
checked & replace if necessary
7
Model EEG-241, 242, 243, 244