6-13. AIR PRESSURE
SWITCHES
Aug. 2014
1. Remove electrical power supplied to the unit.
2. Remove the lower back shroud (See back shroud removal).
3. Remove the pressure switch mounting cover from the
frame.
4. Remove the vacuum hose from switch.
5. Using a phillips bit or screwdriver, remove the two screws
securing switch to the cover.
6. Disconnect the wires on the switch.
7. Replace switch in reverse order.
51