Installation (for qualified installers only)

Extended Baffle (for vent configurations over 6 meters tall)

This insert is shipped with the standard baffle installed. If the vent run exceeds 6 meters, replace the
standard baffle with the included extended baffle.
For vent runs up to 6 meters – The stock baffle is used so no change is need.
For vent runs 6 meters or greater – use the extended baffle AND set the exhaust restrictor
between 4 and 5 (see below for details).

Installation of the Extended Baffle

1. Loosen the three screws on the ceiling of the firebox that secure the stock baffle (two in the front
and one centered in the rear).
2. Slide the baffle forward so the slotted tabs disengage from the screws loosened in the previous
step.
3. Tighten the rear screw but leave the front two loose.
Loosen the
3 screws.
© Travis Industries
Stock Baffle
Baffle
5/2/18-1476
Extended Baffle
Radiant Small GSB2