Approved Vent Configurations

Restrictor Position

A restrictor is built into the appliance to control the flow rate of exhaust gases. This ensures proper
flames for the wide variety of vent configurations. Depending upon the vent configuration, you may be
required to adjust the restrictor position. The charts for approved vent configurations describe which
position the vent restrictor must be in.
To Access the Restrictor
Lift the stove top off the
stove and place it aside.

Measuring Vent Lengths

Vent Height is calculated to
the top of the vent on
horizontal terminations and
to the top of the termination
on vertical terminations.
© Travis Industries
Installation
To Adjust the Restrictor
NOTE:
The restrictor is shipped
in position #1.
Vent
Height
4/20/2018 - 1461
(for qualified installers only)
Slide the restrictor
a
b
adjustment to the
Remove the screw.
correct position.
1/4" Nutdriver
Restrictor
Positions
# 1
# 3
# 5
# 4
# 6
Vent Horizontal Run is
Vent
measured from the start of
Horizontal
the horizontal section to the
Run
end of the termination.
H2
Horizontal
Elbow
H1
Replace the screw
c
through the correct
hole on the restrictor
adjustment rod.
# 2
This restrictor is in
position # 6
Vertical Elbow
NOTE:
When a horizontal elbow (90° or 45°) is
used, horizontal length is the sum of the
two lengths (H1 + H2).