Installing The Outside Air Kit; Wiring The Warmhearth; Installing The Blower Systems - Regency Z2510L Owners & Installation Manual

Warmhearth fireplace
Hide thumbs Also See for Z2510L:
Table of Contents

Advertisement

INSTALLING THE
OUTSIDE AIR KIT
Combustion air is fed to the firebox through a
connection on the rear lower left side of the unit.
A free flowing supply of air must be available
to this opening at all times. Combustion air may
be taken from inside the building if the local
building code allows, but performance may
suffer. Also, it must go through the 4 in. duct
to the connection on the left hand side.
Air drawn from the interior of the building will
affect the performance of gas or oil furnaces,
and exhaust fans and fan driven appliances.
This may cause a negative pressure in the
house allowing smoke to back into the home.
The preferred source of combustion air is from
outside the building. If possible, install the kit on
the wind loading side of the building not the
leeward or (negative pressure) side.
Note: Do not obtain combustion air from
attic, garage or other enclosed
space.
1) Put the supplied insulated air duct to a
nearby exterior wall. Maximum length of
duct is 20 ft. (6.1m). Duct length should be
kept to a minimum and as straight as possi-
ble. Note: 5 ft. only is supplied with unit. If
more than 5 ft. is used, increase the diam-
eter of the duct. Termination should be in an
area with good air flow.
2) Ensure that your air source is not close to
automobile exhaust, gas meters or other
vents.
3) Cut a 4-1/4 in. hole through the wall and
mount the outside air kit.
4) Attach the two ends of the duct (making
sure not to damage the insulating cover)
after installing the flange on the fireplace
side. Duct must be secured by screws or
clamp.
Outside Air Inlet must be 6 ft. below
the chimney termination point
Regency Z2510 WarmHearth

WIRING THE WARMHEARTH

Field wire main power supply to fireplace for fan kit. (All electrical connections should only be
performed by a licensed/certified electrician).
CAUTION:
connection when servicing controls.
Wiring errors can cause improper and
dangerous operation.

INSTALLING THE BLOWER SYSTEMS

The WarmHearth Fireplace has been designed to meet a wide range of heating requirements. The
radiant heat (through the large glass area) combined with the
naturally convected heat, allows the WarmHearth Fireplace to
adequately heat an average sized room. A blower is
recommended to assist in heating a larger area or one
with wall separations. Through
the use of two separate blower
systems, Regency has
developed the three basic
blower wiring options list-
ed in the diagrams below.
Please read all the de-
scriptions before de-
ciding which option is
best suited for your appli-
Blower switch box slides into bottom louver
assembly and is screwed into place. Place
label on outside of louver as shown.
INSTALLATION
Label all wires prior to dis-
OPTION 1
Internal Blower with Thermo-Disc
The thermodisc provides the user with more
convenient control. By leaving the auto/man
switch on AUTO, the thermodisc will shut the
fan off automatically when the fireplace is too
cool to provide adequate heat.
1) Slide blower under side clips (see direc-
tional arrows on diagram) and wire to
terminal box. Note: hardwire terminal box
before drywalling.
2) Blower switch box slides onto bottom lou-
ver and is screwed into place.
3) Place sticker on outside of bottom louver.
cation.
13