Air-Cooled Chimney Adaptor-Metal Fab; Installing The Outside Air Kit - Regency FP90 Owners & Installation Manual

Hide thumbs Also See for FP90:
Table of Contents

Advertisement

installation
|
20
AIR-COOLED CHIMNEY ADAPTOR-
AIR-COOLED CHIMNEY ADAPTOR-
METAL FAB
METAL FAB
1. Attach metal fab/anchor plate/starter collar to the
unit with the minimum of 6 screws.
NOTE: While attaching the metal fab/anchor plate/
starter collar, the UL label should be up and facing the
front of the unit.
2. Once metal fab/anchor plate/starter collar is in-
stalled, proceed with metal fab instructions for the
installation of chimney.
Metal Fab attached to the unit
20 | FP90 Wood Fireplace
919-591
Combustion air is fed to the firebox through a connection on the rear lower left
side of the unit. A free flowing supply of air must be available to this opening
at all times. Combustion air may be taken from inside the building if the local
building code allows, but performance may suffer. Also, it must go through the
6" (152mm) duct to the connection on the left hand side.
Air drawn from the interior of the building will affect the performance of gas or oil
furnaces, and exhaust fans and fan driven appliances. This may cause a nega-
tive pressure in the house allowing smoke to back into the home. The preferred
source of combustion air is from outside the building. If possible, install the kit on
the wind loading side of the building not the leeward or (negative pressure) side.
Note: Do not obtain combustion air from attic, garage or other enclosed
1) Put the supplied insulated air duct to a nearby exterior wall. Maximum
2) Ensure that your air source is not close to automobile exhaust, gas meters
3) Cut a 7" (178mm) hole through the wall and mount the outside air kit.
UL label facing
4) Attach the two ends of the duct (making sure not to damage the insulating
front of the unit
Exterior
Outside
Metal

INSTALLING THE OUTSIDE AIR KIT

space.
length of duct is 20ft (6.1m). Duct length should be kept to a minimum and
as straight as possible. Note: 4 ft. only is supplied with unit. Termination
should be in an area with good air flow.
or other vents.
cover) after installing the flange on the fireplace side. Duct must be secured
by screws or clamp.
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.
WIRING THE FP90
Wall
Insulated Metal
Vent
6 Duct
Outside Air Inlet must be 6 ft. (152mm) below
the chimney termination point
FP90
Side Connection
Unit
08.10.15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic fp90

Table of Contents