installation
Model
CF Sentinal
Super Pro 2100+
Super Vent 2100+
Security S2100+
Oliver Macleod Project HT6000+
Simpson DuraPlus HTC
ICC Excel 2100
eleVation (ft)
aBoVe sea leVel
0ft - 1000ft
(0m - 305m)
1000ft - 2000ft
(305m - 610m)
2000ft - 3000ft
(610m - 914m)
3000ft - 4000ft
(914m - 1219m)
4000ft - 5000ft
(1219m - 1524m)
5000ft - 6000ft
(1524m - 1829m)
6000ft - 7000ft
(1829m - 2134m)
7000ft - 8000ft
(2134m - 2438m)
8000ft - 9000ft
(2438m - 2743m)
9000ft - 10000ft
(2743m - 3048m)
installinG tHe
outside air Kit
Combustion air is fed to the firebox through a
connection on the rear lower left side of the unit.
A free flowing supply of air must be available to
this opening at all times. Combustion air may be
taken from inside the building if the local building
code allows, but performance may suffer. Also,
it must go through the 6" (152mm) duct to the
connection on the left hand side.
Air drawn from the interior of the building will
affect the performance of gas or oil furnaces,
and exhaust fans and fan driven appliances.
This may cause a negative pressure in the
house allowing smoke to back into the home.
16
taBle 1

required firestop, radiation shield, or attic insulation shield

1st floor
Intermediate Joist Shield
Attic Insulation Shield
Attic Insulation Shield
Radiation Shield Fire Stop
Radiation Shield Fire Stop
Fire Stop Radiation Shield
Radiation Shield
taBle 2

Minimum recommended flue Height in feet

(Measured from the top of the solid fuel appliance)
0
2 x 15
4 x 15
o
o
12.00ft
13.00ft
14.00ft
(3.66m)
(3.96m)
(4.27m)
12.48ft
13.52ft
14.56ft
(3.80m)
(4.12m)
(4.44m)
12.96ft
14.04ft
15.12ft
(3.95m)
(4.28m)
(4.61m)
13.44ft
14.56ft
15.68ft
(4.10m)
(4.44m)
(4.78m)
13.92ft
15.08ft
16.24ft
(4.24m)
(4.60m)
(4.95m)
14.40ft
15.60ft
16.80ft
(4.39m)
(4.75m)
(5.12m)
14.88ft
16.12ft
17.36ft
(4.54m)
(4.91m)
(5.29m)
15.36ft
16.64ft
17.92ft
(4.68m)
(5.07m)
(5.46m)
15.84ft
17.16ft
18.48ft
(4.83m)
(5.23m)
(5.63m)
16.32ft
17.68ft
19.04ft
(4.97m)
(5.39m)
(5.80m)
The preferred source of combustion air is from
outside the building. If possible, install the kit
on the wind loading side of the building not the
leeward or (negative pressure) side.
note: do not obtain combustion air from
attic, garage or other enclosed space.
1) Put the supplied insulated air duct to a nearby
exterior wall. Maximum length of duct is 20ft
(6.1m). Duct length should be kept to a
minimum and as straight as possible. note:
4 ft. only is supplied with unit. Termination
should be in an area with good air flow.
2) Ensure that your air source is not close to
automobile exhaust, gas meters or other
vents.
2nd floor into attic
Attic Insulation Shield
Attic Insulation Shield
Attic Insulation Shield
Insulation Radiation Shield Attic Radiation Shield
Insulated Attic Radiation Shield
Attic Insulation Shield
Radiation Shield with Storm Collar
# of elBoWs
2 x 30
4 x 30
2 x 45
o
o
15.0ft
18.00ft
16.00ft
(4.57m)
(5.49m)
(4.88m)
15.6ft
18.72ft
16.64ft
(4.75m)
(5.71m)
(5.07m)
16.2ft
19.44ft
17.28ft
(4.94m)
(5.93m)
(5.27m)
16.8ft
20.16ft
17.92ft
(5.12m)
(6.14m)
(5.46m)
17.4ft
20.88ft
18.56ft
(5.30m)
(6.36m)
(5.66m)
18.0ft
21.60ft
19.20ft
(5.49m)
(6.58m)
(5.85m)
18.6ft
22.32ft
19.84ft
(5.67m)
(6.80m)
(6.05m)
19.2ft
23.04ft
20.48ft
(5.85m)
(7.02m)
(6.24m)
19.8ft
23.76ft
21.12ft
(6.04m)
(7.24m)
(6.44m)
20.4ft
24.48ft
21.76ft
(6.22m)
(7.46m)
(6.63m)
3) Cut a 7" (178mm) hole through the wall and
mount the outside air kit.
4) Attach the two ends of the duct (making
sure not to damage the insulating cover)
after installing the flange on the fireplace
side. Duct must be secured by screws or
clamp.
Exterior
Wall
Outside
Metal
Vent
Outside Air Inlet must be 6 ft. (152mm) below
the chimney termination point
4 x 45
o
o
20.0ft
(6.10m)
20.0ft
(6.10m)
21.6ft
(6.58m)
22.4ft
(6.83m)
23.2ft
(7.07m)
24.0ft
(7.32m)
24.8ft
(7.56m)
25.6ft
(7.80m)
26.4ft
(8.05m)
27.2ft
(8.29m)
Side Connection
Unit
Insulated Metal
6" Duct
FPI FP90 Wood Fireplace