Siemens SIMATIC ET 200SP Manual page 71

Fail-safe modul f-cm as-i safety st 3rk7136-6sc00-0bc1
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Byte.Bit
Description
In the case of binary values, the
description declares the status "1"
4.1
ASIsafe code table teaching active
4.2
Diagnostic memory overflow
4.3
Change of parameters not
permissible
4.4 ... 4.7
Reserved
5.0
Status LED flashes green
5.1
Status LED lit green
5.2
Error LED flashes red
5.3
CFG LED flashes red
5.4
PSF LED flashes red
5.5
Teach LED flashes yellow
5.6
Teach LED lit yellow
5.7
ADDR LED flashes green
6.0
No access possible to the retentive
storage of the F-address
6.1
Different destination address
(F_Dest_Add)
6.2
Invalid target address
(F_Dest_Add)
6.3
Invalid source address
(F_Source_Add)
6.4
Watchdog time is 0 ms
(F_WD_Time or F_WD_Time2)
6.5
Parameter "F_SIL" exceeds the
application-specific SIL
6.6
Parameter "F_CRC_Length" does
not match the generation
6.7
Incorrect F-parameter version or
F_Block_ID
7.0
CRC1 error
7.1
Inconsistent i-parameters (iParCRC
error)
7.2
PROFIsafe communication error
(timeout)
7.3
PROFIsafe communication error
(CRC)
Fail-safe Module F‑CM AS‑i Safety ST (3RK7136‑6SC00‑0BC1)
Manual, 03/2017, A5E03957059020A/RS-AB/002
Assigning parameters / Setting the address space
FW V1.0.1 and
Remark
higher: Error
code (decimal) in
the diagnostic
alarm
-
Teach LED flashes yellow; code sequences are
collected. Is reset when the code tables for all safe
AS-i input slaves detected on the bus have been
taught.
33
Too many simultaneous error messages
-
Modification of parameter data is rejected in normal
mode
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
781
The coding element (type H) in the BaseUnit is
missing or there is an access error
64
The PROFIsafe driver has detected a different F-
destination address.
65
The PROFIsafe driver has detected an inadmissible
F-destination address.
66
The PROFIsafe driver has detected an inadmissible
F-source address.
67
The PROFIsafe driver has detected an inadmissible
watchdog time.
68
The PROFIsafe driver has detected a discrepancy
between the communication SIL setting and the
application SIL setting.
69
The PROFIsafe driver has detected a discrepancy
in the CRC length.
70
The PROFIsafe driver has detected an incorrect
version of the F-parameters or an invalid
F_Block_ID.
71
The PROFIsafe driver has detected inconsistent F-
parameters.
75
The PROFIsafe driver has detected inconsistent i-
parameters.
92
F93
6.4 Data records for diagnostics
71