Citizen CL-E321 User Manual page 57

Line thermal printer
Hide thumbs Also See for CL-E321:
Table of Contents

Advertisement

Home menu
Sub menu
System Setup
Sensor Level
Paper End Level 3.00 V
Error Reporting On Printing
Buzzer Select
Metric/Inch
Max Media
Length
Settings Lock
Keyboard Lock
Control Code
Media Power Up Off
CI Lock
Emulation Select DM4
Emulation Auto
Detect
Default
Configurable range
1.5 V
0.0 V to 3.3 V
0.01 V to 3.30 V
On Printing
Immediate
Exec/Err
Exec/Err
All
Error
Key
None
Inch
Inch
mm
10.00 inch
CL-E321:
254.0 mm
(Datamax)
0.25 to 99.99 inch
6.4 to 2539.7 mm
(Zebra)
0.25 to 100.00 inch
6.4 to 2540.0 mm
CL-E331:
1.00 to 50.00 inch
25.4 to 1,270.0 mm
Off
On
Off
Off
On
Off
STD
STD
ALT
ALT-2
On
Off
Off
On
Off
DM4
(Datamax®)
DMI
ZPI2 (Zebra®)
DPP
ZPI2
Full Auto
On
Off
Full Auto
57
Notes
Sets the sensor threshold
Sets the paper end level
Error reporting setting
Sets the conditions at which the
buzzer is triggered
Sets the unit of measure
Sets the maximum length of label
media
Prevents changes via setting com-
mands
Prevents changes via key operation
Changes the command mode for
DMX mode (only when Datamax®
emulation is selected)
Sets the media length measuring
function when the power is turned
on (only when Zebra® emulation
mode is selected on international
models)
Prevents changes via CI com-
mands (only when Zebra® emula-
tion mode is selected on interna-
tional models)
Datamax®/Zebra® compatibility
selection
DM4 Datamax® 400
DMI Datamax® IClassTM
DPP Datamax® Prodigy Plus®
ZPI2 Zebra® ZPL2 ®
Sets the emulation sensing function
(international models only)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl-e331

Table of Contents