Create A Group Of Linked Search Banks - AOR AR-DV10 Operating Manual

Hide thumbs Also See for AR-DV10:
Table of Contents

Advertisement

9.4.

CREATE A GROUP OF LINKED SEARCH BANKS

There are 10 search groups (numbered 0 to 9) that may be set up individually to search a
group of linked search banks. Each search group can be setup with its own squelch
parameters as follows:
Delay time: Time between the signal dropout and squelch closing, for search to resume.
Free time: The time after which scanning will resume, whether or not the signal drops
out.
Auto store: The first 50 active frequencies located during scanning are automatically
saved in memory bank 39, for later review and scanning.
How to create a search group:
1.
Press [MENU], then use the [▶] button to select
[SRCH] and then press [ENT].
2.
Use the [▶] button to select [GRP EDIT] and then
press [ENT] twice.
3.
Use the keypad to enter the search group number to
be created.
This illustration shows an example of search group 0
and all search bank numbers from 00 to 39 which
can be linked, providing of course they have already
been programmed.
4.
Pressing the [▶] button followed by [ENT], will select the first bank 00 (the selected bank
will blink).
For example: to link banks 00 and 01:
5.
Press the [.] key to register bank 00.
6.
Use the [▶] button to move to bank 01 and press the [.] key to register bank 01. (You can
also rotate the dial knob to rapidly scroll through the bank numbers)
If a bank number is selected by mistake, it may be unselected with the [.] key.
The linked banks 00 and 01 will appear as follows:
00 01 02 03 04 05 06 07 08 09
10 11 12 13 14 15 16 17 18 19
20 21 22 23 24 25 26 27 28 29
30 31 32 33 34 35 36 37 38 39
7.
Press the [9] key to save the search bank link selection and move to the following
settings for [DELAY TIME].
Delay time:
This is the time between signal dropout and squelch closing, for search to resume.
It can be set between 0.1 and 10 seconds, in 0.1 second increments.
[OFF] is no delay.
Default is 2 seconds.
Press [ENT] and rotate the dial knob to select the desired delay time.
Press [ENT] to confirm the delay time setting and advance the operation to [FREE] time
setting.
39

Advertisement

Table of Contents
loading