PFI

Timing Signals
Static DO
Buffer
To Input Timing
Signal Selectors
© National Instruments Corporation
M Series devices have up to 16 Programmable Function Interface (PFI)
signals. In addition, M Series devices have up to 32 lines of bidirectional
DIO signals.
Each PFI can be individually configured as the following.
A static digital input
A static digital output
A timing input signal for AI, AO, DI, DO, or counter/timer functions
A timing output signal from AI, AO, DI, DO, or counter/timer
functions
Each PFI input also has a programmable debouncing filter. Figure 8-1
shows the circuitry of one PFI line. Each PFI line is similar.
Direction Control
Static DI
Filters
Weak Pull-Down
PFI
Figure 8-1. M Series PFI Circuitry
8-1
I/O Protection
PFI x/P1/P2
M Series User Manual
8