Scanning operating conditions

1. Press c.
2. Select the required operating
mode scan with a or b.
The following operating conditions can be scanned subject to the actual
equipment level:
Heating circuits A1 and M2
H Holiday program with departure
and return date
H Actual outside temperature
H Actual boiler temperature
H Actual flue gas temperature
H Actual DHW temperature
H Actual flow temperature
(only with mixer circuits)
H Actual return temperature
(only with mixer circuits)
H Standard room temp. (set value)
H Actual room temperature
H Actual solar DHW temperature
H Collector temperature
H Burner, hours run
H Burner starts
H Consumption
H Solar energy in kWh
H Time
H Date
H Burner ON/OFF
H Cylinder primary pump ON/OFF
H DHW circulation pump ON/OFF
H Heating circuit pump ON/OFF
H Mixer open/closed
H Solar circuit pump ON/OFF
H Hours run, solar circuit pump
H Various languages
3. Press c.
If a holiday program has been
entered.
For coding address C7, a value
higher than 0 must be selected.
If a remote control unit is
connected.
In conjunction with solar system.
In conjunction with solar system.
Reset hours run, burner starts and
consumption after maintenance.
The individual values can be
reset to 0 with e.
Display only if 26 or 29 is set via
the coding addresses.
In conjunction with solar system.
In conjunction with solar system.
In conjunction with solar system.
Each language can be selected as
the permanent display language
with d.
Service scans