Finish the installation by completely tightening the screws in the same sequence.
c.
Install all components removed from the failed system board.
11.
Connect all cables disconnected from the failed system board.
12.
If removed, install the dedicated iLO management module.
13.
If removed, install the rear drive cage and connect the drive backplane cables.
14.
If removed, install the PCI riser cage.
15.
Install the cable management holder.
16.
Install the air baffle.
17.
Install the access panel.
18.
Install the server into the rack.
19.
Connect each power cord to the server.
20.
Connect each power cord to the power source.
21.
Press the Power On/Standby button.
22.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
IMPORTANT:
system board.
After you replace the system board, you must re-enter the server serial number and the product ID.
During the server startup sequence, press the F9 key to access UEFI System Utilities.
1.
Select the System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options >
2.
Advanced System ROM Options > Serial Number, and then press the Enter key.
Enter the serial number and press the Enter key. The following message appears:
3.
The serial number should only be modified by qualified service personnel.
This value should always match the serial number located on the chassis.
Press the Enter key to clear the warning.
4.
Enter the serial number and press the Enter key.
5.
Select Product ID. The following warning appears:
6.
Install all components with the same configuration that was used on the failed
DRAFT - HP Confidential - DRAFT
Removal and replacement procedures 110