Service and Repair Manual
Platform Controls
15 When ramp time has been achieved, activate
the drive enable toggle switch to the right to
save your changes.
Result: The alarm should sound indicating the
setting has been saved.
16 Repeat steps 11 through 13 for each machine
function.
To exit programming mode:
17 Move and hold the drive enable toggle switch
in the left direction until the display screen
returns to SYSTEM READY.
Ramp down time (factory settings)
Primary boom up/down
decelerate
Secondary boom up/down
decelerate
Turntable rotate
decelerate
Extend/Retract
decelerate
Jib up/down
decelerate
Platform rotate
decelerate
Jib rotate (if equipped)
decelerate
20
How to Adj ust the Max Speed Driv e Settings
How to Adjust the Max Speed
Drive Settings
Adjusting the max speed setting will only affect the
stowed drive speed. Elevated drive speed is not
adjustable.
Note: Begin this procedure with the machine in the
stowed position.
1
Turn the key switch to platform control.
2
Pull out the red Emergency Stop button to the
'ON' position at both the ground and platform
controls.
3
Move and hold the drive enable toggle switch
in the right direction while holding the steer
rocker switch in the right direction.
1.5 second
4
When the display leaves SYSTEM READY
mode, release the drive enable toggle switch
0.65 second
and the steer rocker switch.
Result: The display will show FAULTS.
0.25 second
5
Momentarily activate the steer rocker switch in
the right direction until SETTINGS is shown on
0.5 seconds
the display.
6
Momentarily activate the drive enable toggle
0.25 second
switch in the right direction until VALVE AND
PUMP SETTINGS is shown on the display.
0.15 second
7
Momentarily activate the steer rocker switch in
the right direction until you see the
0.25 seconds
AUTHORIZATION screen.
8
Momentarily activate the drive enable toggle
switch in the right direction to enter the
authorization screen.
Z-40/23N, Z-40/23N RJ
September 2016
Part No. 1268528