CHAPTER 6: OPERATOR TROUBLESHOOTING
6.2
Troubleshooting Fryers and Controllers
BURNER(S)
WON'T LIGHT.
Are any
control panel lights
illuminated?
Yes
Verify gas valve(s) is/are
in ON position and that
main gas supply valve is
open. If unit is equipped
with built-in filtration
system, verify drain
valve(s) is/are fully
closed. Press ON/OFF
switch OFF, then back
ON.
Did
burner(s) light?
No
Press ON/OFF switch
OFF. Disconnect gas
line quick-disconnect
fitting and reconnect.
Press power switch
ON, wait 30 seconds,
turn power switch OFF.
Repeat 3 more times to
purge air from gas line.
G18FB & G24FB SERIES GAS FRYERS
Verify unit is plugged into a
live circuit with main circuit
No
breaker in ON position.
Press ON/OFF switch OFF,
then back ON.
Did
No
burner(s) light?
Yes
Problem
Yes
resolved.
Yes
Did
burner(s) light?
6-2
Problem is beyond
scope of operator
No
troubleshooting. Call FASC or
Frymaster Service
Department.