For example, entering "30" means the
product needs to be shaken after it has
been cooking for 30 seconds. At the end
of one minute, an alarm will sound and the
product switch will flash for 3 seconds. If
your product does not require shaking,
enter "0". The number entered will appear
in the right display. Press [ [ [ [ to lock in the
programmed time.
9. hd_
hd_ (Hold Time) will appear in the left
hd_
hd_
display. Set the time the product may be
held before serving, anything from 13 sec-
onds to 60 minutes. If you do not wish to
use the hold time feature, enter 0. Press [ [ [ [
to lock in the time.
10. selp
selp (Select Product) will again appear in
selp
selp
the left display. If more products are to be
programmed, return to Step 5 and follow
all instructions to this point, repeating for
each product.
11. When programming is completed, lock in
the whole program by pressing the Tem-
perature Check/Program Lock Switch
USING THE BOIL-OUT FEATURE
CAUTION
Before using this feature, ensure the
frypot is filled with a mixture of cold
water and Frymaster FRYER 'N'
GRIDDLE cleaner or detergent.
1. To program the fryer for boil-out, press the
Power Switch
(or ON/OFF
followed by the Program Mode Switch [ [ [ [ .
Code will appear in the left display.
Code
Code
Code
2. Enter the code number 1 6 5 3. The right
display will read boil
boil. The temperature is
boil
boil
G18FB & G24FB SERIES GAS FRYERS
CHAPTER 3: OPERATING INSTRUCTIONS
.
ON
Switch)
OFF
automatically set for 195ºF (91ºC). The
fryer will attain this temperature and
remain there until the Power
ON
ON/OFF
) Switch is pressed, which
OFF
cancels the boil-out mode. In high-altitude
locations, the fryer must be monitored
constantly for boil-over conditions.
boil-over occurs, turn off the fryer
immediately, allow it to cool, then re-enter
the boil-out mode to continue the boil-out
process.
FRYER RECOVERY TIME CHECK FEATURE
1. The computer automatically checks the
recovery time each time the frypot tem-
perature drops below 250ºF (121ºC). To
check recovery time, press the Program
Mode Switch [ [ [ [ . Code
left display.
2. Enter the code number 1 6 5 2 on the num-
ber keypad. The recovery time will appear
in both displays for 5 seconds.
SELECTING FAHRENHEIT– CELSIUS DISPLAY
MODE
1. The computer can display temperatures in
either Fahrenheit or Celsius. To change
from one to the other, press the Program
Mode Switch [ [ [ [ . Code
left display.
2. Enter the code number 1 6 5 8 on the num-
ber keypad. The computer will toggle the
temperature display from Celsius to Fahr-
enheit or from Fahrenheit to Celsius.
3. Press the Temperature Check/Program
Lock Switch
in the newly selected mode.
3-6
Code will appear in the
Code
Code
Code will appear in the
Code
Code
to display the temperature
(or