Operating Instructions
Micropilot M FMR230
Level-Radar
BA00225F/00/EN/13.11
71139431
Valid as of software version:
01.04.00

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Micropilot M FMR230

  • Page 1 Operating Instructions Micropilot M FMR230 Level-Radar BA00225F/00/EN/13.11 71139431 Valid as of software version: 01.04.00...
  • Page 2 Brief operating instructions Micropilot M FMR230 PROFIBUS PA Brief operating instructions Micropilot M FMR230, FMR231 - Brief operating instructions KA159F/00/a2/08.06 52006292 Contrast: measured value dist./ meas value Group selection basic setup tank shape medium process empty full pipe dist./ check...
  • Page 3 Basic Setup with the Endress+Hauser oprating program ... . . 69 Maintenance....73 Accessories.
  • Page 4: Safety Instructions

    Safety instructions Micropilot M FMR230 PROFIBUS PA Safety instructions Designated use The Micropilot M is a compact radar level transmitter for the continuous, contactless measurement of liquids, pastes and sludge. The device can also be freely mounted outside closed metal vessels because of its operating frequency of about 6 GHz and a maximum radiated pulsed energy of 1 mW (average power output 1 μW).
  • Page 5: Notes On Safety Conventions And Symbols

    Micropilot M FMR230 PROFIBUS PA Safety instructions Notes on safety conventions and symbols In order to highlight safety-relevant or alternative operating procedures in the manual, the following conventions have been used, each indicated by a corresponding symbol in the margin.
  • Page 6: Identification

    Identification Micropilot M FMR230 PROFIBUS PA Identification Device designation 2.1.1 Nameplate The following technical data are given on the instrument nameplate: ENDRESS+HAUSER Order Code: Ser.-No.: if modification see sep. label Dat./Insp.: Information on the nameplate of the Micropilot M Instrument designation...
  • Page 7 Micropilot M FMR230 PROFIBUS PA Identification 2.1.2 Ordering structure This overview does not mark options which are mutually exclusive. Approval A Non-hazardous area Non-hazardous area, WHG ATEX II 1/2G Ex ia IIC T6, IECEx Zone 0/1 ATEX II 1/2G Ex ia IIC T6, XA, IECEx Zone 0/1, Note safety instruction (XA) (electrostatic charging)!
  • Page 8 Identification Micropilot M FMR230 PROFIBUS PA Process Connection 10K 150A RF, 316Ti flange JIS B2220 10K 200A RF, 316Ti flange JIS B2220 10K 250A RF, 316Ti flange JIS B2220 Tri-Clamp ISO2852 DN70-76.1 (3"), 316Ti 6" 150lbs FF, AlloyC4, purge flange ANSI B16.5 NUS Special version, TSP-no.
  • Page 9: Scope Of Delivery

    The device complies with the applicable standards and regulations as listed in the EC declaration of conformity and thus complies with the statutory requirements of the EG directives. Endress+Hauser confirms the successful testing of the device by affixing to it the CE mark.
  • Page 10: Mounting

    Mounting Micropilot M FMR230 PROFIBUS PA Mounting Quick installation guide Observe orientation when installing! Installation in tank (free space): Mark on process connector facing the nearest tank wall! Turn housing The housing can be turned 350° mark at instrument flange...
  • Page 11: Incoming Acceptance, Transport, Storage

    Micropilot M FMR230 PROFIBUS PA Mounting Incoming acceptance, transport, storage 3.2.1 Incoming acceptance Check the packing and contents for any signs of damage. Check the shipment, make sure nothing is missing and that the scope of supply matches your order.
  • Page 12: Installation Conditions

    Mounting Micropilot M FMR230 PROFIBUS PA Installation conditions 3.3.1 Dimensions Housing dimensions 65 (2.56) 78 (3.07) max. 110 (4.33) ENDRESS+HAUSER F12 housing (Aluminium) 85 (3.35) mm (in) L00-F12xxxx-06-00-00-en-001 65 (2.56) max. 100 (4.33) 94 (3.7) 78 (3.07) ENDRESS+HAUSER T12 housing (Aluminium) 85 (3.35)
  • Page 13 Micropilot M FMR230 PROFIBUS PA Mounting Process connection, type of antenna F12 / T12 / F23 housing R = reference point of measurement Group 30 / Code L Group 30 / Code M High temperature version Ext. temperature version ø60 ø60...
  • Page 14 Mounting Micropilot M FMR230 PROFIBUS PA 3.3.2 Engineering hints Orientation • Recommended distance (1) wall – outer edge of nozzle: ~1/6 of tank diameter. Nevertheless the device should not be installed closer than 30 cm (11.8 in) to the tanwall.
  • Page 15 Micropilot M FMR230 PROFIBUS PA Mounting Measurement in a plastic tank If the outer wall of the tank is made of a non-conductive material (e.g. GRP), microwaves can also be reflected off interfering installations outside the signal beam (e.g. metallic pipes (1), ladders (2), grates (3), …).
  • Page 16 Mounting Micropilot M FMR230 PROFIBUS PA Measuring conditions Note! • In case of boiling surfaces, bubbling or tendency for foaming, use FMR230 or FMR231. Depending on its consistence, foam can either absorb microwaves or reflect them off the foam surface. Measurement is possible under certain conditions.
  • Page 17 Micropilot M FMR230 PROFIBUS PA Mounting Measuring range The usable measuring range depends on the size of the antenna, the reflectivity of the medium, the mounting location and eventual interference reflections. The maximum configurable range is: • 20 m (66 ft) The following tables describe the groups of media as well as the achievable measuring range as a function of application and media group.
  • Page 18: Installation Instructions

    Mounting Micropilot M FMR230 PROFIBUS PA Installation instructions 3.4.1 Mounting kit In addition to the tool needed for flange mounting, you will require the following tool: • 4 mm (0.16 in) Allen wrench for turning the housing or mounting an FAR10 antenna extension.
  • Page 19 Micropilot M FMR230 PROFIBUS PA Mounting Antenna extension FAR10 When mounting an antenna extension, please note the following points: FMR230 • The antenna extension has to be selected such that the horn extends below the nozzle. • If the horn diameter is greater than the ≥...
  • Page 20 Mounting Micropilot M FMR230 PROFIBUS PA Special extensions • If the antenna has to be mounted on a sloping FMR230 or vertical vessel wall, an extension with a 45° respectively 90° bend is available. • The smallest possible radius R for the bend is 300 mm (11.8 in).
  • Page 21 Micropilot M FMR230 PROFIBUS PA Mounting Installation with heat insulation high temperature version (type of antenna M) extended temperature version (type of antenna L) tank insulation tank insulation max. 280°C (536°F) max. 400°C (752°F) L00-FMR230xx-17-00-00-en-019 • To avoid the electronics heating up as a result of heat radiation or convection, the FMR230 must be incorporated into the tank insulation at high process temperature (≥...
  • Page 22 Mounting Micropilot M FMR230 PROFIBUS PA 3.4.3 Installation in stilling well Optimum mounting position marker at instrument flange or threaded boss 1½” BSPT (R 1½”), G 1½" (FMR 244) DN50 DN80…150 1½ NPT ANSI 2” ANSI 3…6” L00-FMR230xx-17-00-00-en-006 Standard installation For installations in a stilling well, follow the engineering hints (→...
  • Page 23 Micropilot M FMR230 PROFIBUS PA Mounting Examples for the construction of stilling wells Micropilot M FMR230 marker e.g. welding neck flange DIN 2633 stilling well 100 % with slots hole <1/10 pipe-ø, < 1/10 pipe-ø single sided or drilled through...
  • Page 24 Mounting Micropilot M FMR230 PROFIBUS PA 3.4.4 Installation in bypass Optimum mounting position L00-FMR230xx-17-00-00-en-007 Standard installation For installations in a bypass, follow the engineering hints (→ ä 14) and note the following points: • Marker is aligned perpendicular (90°) to tank connectors.
  • Page 25 Micropilot M FMR230 PROFIBUS PA Mounting Example for the construction of a bypass Micropilot M FMR230, FMR240, FMR244 - 80 (3"), FMR245 marker e.g. welding neck flange DIN 2633 full bore ball valve 100% Diameter of the connection pipes as small as possible...
  • Page 26: Post-Installation Check

    Mounting Micropilot M FMR230 PROFIBUS PA 3.4.5 Turn housing After mounting, the housing can be turned 350° in order to simplify access to the display and the terminal compartment. Proceed as follows to turn the housing to the required position: •...
  • Page 27: Wiring

    Micropilot M FMR230 PROFIBUS PA Wiring Wiring Quick wiring guide Wiring in F12/F23 housing " Before connection please note the following: ENDRESS+HAUSER Made in Germany MICROPILOT M PROFIBUS devices are marked on the nameplate (1). The D-79689 Maulburg Order Code:...
  • Page 28 Wiring Micropilot M FMR230 PROFIBUS PA Wiring in T12 housing " Before connection please note the following: ENDRESS+HAUSER PROFIBUS devices are marked on the nameplate (1). Made in Germany MICROPILOT M D-79689 Maulburg Order Code: FMR2xx-14EALJAA2A The voltage is determined by the PROFIBUS standard Caution! Ser.-No.:...
  • Page 29 Micropilot M FMR230 PROFIBUS PA Wiring Wiring with M12 connector Before connection please note the following: " ● PROFIBUS devices are marked on the nameplate (1). ENDRESS+HAUSER Made in Germany MICROPILOT M D-79689 Maulburg The voltage is determined by the PROFIBUS PA standard...
  • Page 30: Connecting The Measuring Unit

    Wiring Micropilot M FMR230 PROFIBUS PA Connecting the measuring unit Cable entry • Cable gland: M20x1.5 (for Ex-d: cabel entry) • Cable entry: G½ or ½NPT • PROFIBUS-PA M12 plug Supply voltage The following values are the voltages across the terminals directly at the instrument:...
  • Page 31: Recommanded Connection

    Micropilot M FMR230 PROFIBUS PA Wiring Recommanded connection For maximum EMC protection please observe the following points: • The external ground terminal on the transmitter must be connected to ground. • The continuity of the cable screening between tapping points must be ensured.
  • Page 32: Operation

    Operation Micropilot M FMR230 PROFIBUS PA Operation Quick operation guide ENDRESS + HAUSER – >3 s Return to basic setup tank shape medium property Group Selection dome ceiling unknown safety settings horizontal cyl DC: < 1.9 bypass DC: 1.9 ... 4...
  • Page 33 Micropilot M FMR230 PROFIBUS PA Operation 5.1.1 General structure of the operating menu The operating menu is made up of two levels: • Function groups (00, 01, 03, …, 0C, 0D): The individual operating options of the instrument are split up roughly into different function groups. The function groups that are available include, e.g.: "basic setup", "safety settings", "output", "display", etc.
  • Page 34: Display And Operating Elements

    Operation Micropilot M FMR230 PROFIBUS PA Display and operating elements (liquid crystal display) Orde Orde Ser.- Ser.- r Cod r Cod No.: No.: sber surin sber surin eich eich g rang g rang U 16... U 16... 4...2 4...2 0 mA...
  • Page 35 Micropilot M FMR230 PROFIBUS PA Operation 5.2.1 Display Liquid crystal display (LCD): Four lines with 20 characters each. Display contrast adjustable through key combination. Headline Position indicator ENDRESS + HAUSER Symbol Main value Bargraph Unit – Selection list Function groups -> Functions HOME F000 F001 F002 F003 F004 ...
  • Page 36 Operation Micropilot M FMR230 PROFIBUS PA 5.2.3 Key assignment The operating elements are located inside the housing and are accessible for operation by opening the lid of the housing. Function of the keys Key(s) Meaning Navigate upwards in the selection list.
  • Page 37: Local Operation

    Micropilot M FMR230 PROFIBUS PA Operation Local operation 5.3.1 Locking of the configuration mode The Micropilot can be protected in two ways against unauthorised changing of instrument data, numerical values or factory settings: Function "unlock parameter" (0A4): A value <> 2457 (e.g. 2450) must be entered in "unlock parameter" (0A4) in the "diagnostics"...
  • Page 38 There is no need to change these parameters under normal circumstances and consequently, they are protected by a special code known only to the Endress+Hauser service organization. Please contact Endress+Hauser if you have any questions.
  • Page 39 Micropilot M FMR230 PROFIBUS PA Operation 5.3.3 Factory settings (Reset) " Caution! A reset sets the instrument back to the factory settings. This can lead to an impairment of the measurement. Generally, you should perform a basic setup again following a reset.
  • Page 40: Display And Acknowledging Error Messages

    Operation Micropilot M FMR230 PROFIBUS PA Display and acknowledging error messages Type of error Errors that occur during commissioning or measuring are displayed immediately on the local display. If two or more system or process errors occur, the error with the highest priority is the one shown on the display.
  • Page 41: Profibus Pa Communication

    Micropilot M FMR230 PROFIBUS PA Operation PROFIBUS PA communication 5.5.1 Synopsis personal computer e.g. with FieldCare and Profiboard resp. Proficard segment coupler PROFIBUS DP ENDRESS + HAUSER PROFIBUS PA operating and display module ENDRESS + HAUSER – Commubox FXA 291...
  • Page 42 Operation Micropilot M FMR230 PROFIBUS PA 5.5.2 Device address Selecting the device address • Every PROFIBUS-PA device must be given an address. If the address is not set correctly, the device will not be recognised by the process control system.
  • Page 43 (.gsd). The Micropilot M has the ID number 0x152D (hex) = 5421 (dec). Source of supply • Internet (ftp-Server): ftp://194.196.152.203/pub/communic/gsd/Micropilot_m.EXE • CD-ROM with GSD files for all Endress+Hauser devices. Order-Code: 50097200 • GSD library of the PROFIBUS User Organisation (PNO):http: //www.PROFIBUS.com Directory structure The files are oranized in the folowing strucutre: L00-FMR23xxx-02-00-00-de-001 •...
  • Page 44 Operation Micropilot M FMR230 PROFIBUS PA 5.5.4 Cyclic data exchange Block model of the Micropilot M L00-FMR230xx-02-00-00-en-001 The block model shows, which data are exchanged continously (i.e. by cyclic data transfer) between the Micropilot M and the PLC. The numbers refer to the function groups and functions: •...
  • Page 45 Micropilot M FMR230 PROFIBUS PA Operation Configuration of the cyclic data telegram Use the configuration software of your PLC in order to compose the data telegram from these modules in one of the following ways: Main value In order to transmit the main measured value, selct the module "Main Process Value".
  • Page 46 Operation Micropilot M FMR230 PROFIBUS PA IEEE-745 Floating Point Number The measured value is transmitted as a IEEE 754 floating point number, whereby (E-127) Measured value = (-1) x (1+F) Byte 1 Byte 2 Bit 7 Bit 6 Bit 5...
  • Page 47 Micropilot M FMR230 PROFIBUS PA Operation 5.5.5 Acyclic data exchange Acyclic data exchange allows device parameters to be changed independently of the communication between the device and a PLC. Acyclic data exchange is used to... • ... transmit device parameters during commissioning and maintenance;...
  • Page 48 The Analog-Input and physical blocks contain standard parameters, block parameters and manufacturer-specific parameters. The transducer block of the Micropilot M is Endress+Hauser specific. The parameters of the Analog-Input block are not available when operating via the display or via FieldCare.
  • Page 49 Micropilot M FMR230 PROFIBUS PA Operation Parameter Endress+Hauser Slot Index Size Type Read Write Storage Matrix (CW II) [bytes] Class HI HI Limit FLOAT static HI Limit FLOAT static LO Limit FLOAT static LO LO Limit FLOAT static 44-45 HI HI Alarm...
  • Page 50 Operation Micropilot M FMR230 PROFIBUS PA Parameter Endress+Hauser Slot Index Size Type Read Write Storage Matrix (CW II) [bytes] Class Diagnosis mask OSTRING constant Diagnosis mask OSTRING constant ext. Device certification OSTRING constant Security locking V9H9 UNSIGNED16 non-vol. Factory reset...
  • Page 51 Micropilot M FMR230 PROFIBUS PA Operation Endress+Hauser specific level transducer block Parameter Endress+Hauser Slot Index Size Type Read Write Storage Matrix (CW II) [bytes] Class Standard parameters Block data DS-32* constant Static revision UNSIGNED16 non-vol. Device tag OSTRING static Strategy...
  • Page 52 Operation Micropilot M FMR230 PROFIBUS PA Parameter Endress+Hauser Slot Index Size Type Read Write Storage Matrix (CW II) [bytes] Class pres. map. dist. V4H4 FLOAT dynamic cust. Tank map V4H5 UNSIGNED8 static echo quality V4H6 UNSIGNED8 dynamic offset V4H7 FLOAT...
  • Page 53 Micropilot M FMR230 PROFIBUS PA Operation Parameter Endress+Hauser Slot Index Size Type Read Write Storage Matrix (CW II) [bytes] Class antenna ext. VAH9 FLOAT static input level semi V3H4 FLOAT dynamic auto input level manual V3H4 FLOAT static simulation level...
  • Page 54 FieldCare is an Endress+Hauser asset management tool based on FDT technology. With FieldCare, you can configure all Endress+Hauser devices as well as devices from other manufacturers that support the FDT standard. Hardware and software requirements you can find on the internet: www.endress.com ➞...
  • Page 55 Micropilot M FMR230 PROFIBUS PA Operation Signal analysis via envelope curve MicropilotM-en-306 Tank linearisation MicropilotM-en-307 Endress+Hauser...
  • Page 56: Commissioning

    Commissioning Micropilot M FMR230 PROFIBUS PA Commissioning Function check Make sure that all final checks have been completed before you start up your measuring point: • Checklist "Post installation check", → ä 26. • Checklist "Post connection check", → ä 31.
  • Page 57: Basic Setup

    Micropilot M FMR230 PROFIBUS PA Commissioning Basic Setup tank shape flange: dome ceiling reference point of measurement measuring cond. Unknown measuring cond. Standard empty calibr. full calibr. pipe diameter (for bypass/stilling well) mapping E = empty calibr. (= zero) setting in 005 F = full calibr.
  • Page 58 Commissioning Micropilot M FMR230 PROFIBUS PA " Caution! The basic setup is sufficient for successful commissioning in most applications. Complex measuring operations necessitate additional functions that the user can use to customise the Micropilot as necessary to suit his specific requirements. The functions available to do this are described in detail in the BA00221F/00/EN.
  • Page 59: Basic Setup With The Device Display

    Micropilot M FMR230 PROFIBUS PA Commissioning Basic Setup with the device display Function "measured value" (000) ⇒ ENDRESS + HAUSER – This function displays the current measured value in the selected unit (see "customer unit" (042) function). The number of digits after decimal point can be selected in the "no.of decimals"...
  • Page 60 Commissioning Micropilot M FMR230 PROFIBUS PA Function "medium property" (003) ⇒ ENDRESS + HAUSER – This function is used to select the dielectric constant. Selection: • unknown • DC: < 1.9 • DC: 1.9 ... 4 • DC: 4 ... 10 •...
  • Page 61 Micropilot M FMR230 PROFIBUS PA Commissioning Function "process cond." (004) ⇒ ENDRESS + HAUSER – This function is used to select the process conditions. Selection: • standard • calm surface • turb. surface • agitator • fast change • test: no filter...
  • Page 62 Commissioning Micropilot M FMR230 PROFIBUS PA Function "empty calibr." (005) ⇒ ENDRESS + HAUSER – This function is used to enter the distance from the flange (reference point of the measurement) to the minimum level (=zero). L00-FMR2xxxx-14-00-06-en-008 " Caution! For dish bottoms or conical outlets, the zero point should be no lower than the point at which the radar beam hits the bottom of the tank.
  • Page 63 Micropilot M FMR230 PROFIBUS PA Commissioning Function "pipe diameter" (007) ⇒ ENDRESS + HAUSER – This function is used to enter the pipe diameter of the stilling well or bypass pipe. 100% 100% ø ø L00-FMR2xxxx-14-00-00-en-011 Microwaves propagate more slowly in pipes than in free space. This effect depends on the inside diameter of the pipe and is automatically taken into account by the Micropilot.
  • Page 64 Commissioning Micropilot M FMR230 PROFIBUS PA Function "check distance" (051) ⇒ ENDRESS + HAUSER – This function triggers the mapping of interference echoes. To do so, the measured distance must be compared with the actual distance to the product surface. The following options are available for...
  • Page 65 Micropilot M FMR230 PROFIBUS PA Commissioning Function "range of mapping" (052) ⇒ ENDRESS + HAUSER – This function displays the suggested range of mapping. The reference point is always the reference point of the measurement (→ ä 57). This value can be edited by the operator.
  • Page 66 Commissioning Micropilot M FMR230 PROFIBUS PA 6.4.2 Envelope curve with device display After the basic setup, an evaluation of the measurement with the aid of the envelope curve ("envelope curve" (0E) function group) is recommended. Function "plot settings" (0E1) ⇒...
  • Page 67 Micropilot M FMR230 PROFIBUS PA Commissioning Function "envelope curve display" (0E3) The envelope curve is displayed in this function. You can use it to obtain the following information: quality of evaluated echo full calibr. evaluated echo is marked empty calibr.
  • Page 68 Commissioning Micropilot M FMR230 PROFIBUS PA Move mode Then press to switch to Move mode. Either is displayed. • shifts the curve to the right. • shifts the curve to the left. L00-FMxxxxxx-07-00-00-yy-008 Vertical Zoom mode Press once more to switch to Vertical Zoom mode.
  • Page 69: Endress+Hauser Oprating Program

    Micropilot M FMR230 PROFIBUS PA Commissioning Basic Setup with the Endress+Hauser oprating program To carry out the basic setup with the operating program, proceed as follows: • Start the operating program and establish a connection. • Select the "basic setup" function group in the navigation window.
  • Page 70 Commissioning Micropilot M FMR230 PROFIBUS PA Basic Setup step 2/4: • Enter the application parameters: – Tank shape – Medium property – Process cond. MicropilotM-en-302 Basic Setup step 3/4: If "dome ceiling", "horizontal cyl", "..." is selected in the "tank shape" function, the following display appears on the screen: •...
  • Page 71 Micropilot M FMR230 PROFIBUS PA Commissioning Basic Setup step 4/4: • This step starts the tank mapping • The measured distance and the current measured value are always displayed in the header MicropilotM-en-304 6.5.1 Signal analysis via envelope curve After the basic setup, an evaluation of the measurement using the envelope curve is recommended.
  • Page 72 Commissioning Micropilot M FMR230 PROFIBUS PA 6.5.2 User-specific applications (operation) For details of setting the parameters of user-specific applications, see separate documentation BA00221F/00/EN "Description of Instrument Functions" on the enclosed CD-ROM. Endress+Hauser...
  • Page 73: Maintenance

    Repairs The Endress+Hauser repair concept assumes that the measuring devices have a modular design and that customers are able to undertake repairs themselves (→ ä 84, "Spare Parts"). Please contact Endress+Hauser Service for further information on service and spare parts.
  • Page 74: Accessories

    L00-FMR2xxxx-00-00-06-en-001 Commubox FXA291 The Commubox FXA291 connects Endress+Hauser field instruments with CDI interface (= Endress+Hauser Common Data Interface) to the USB interface of a personal computer or a notebook. For details refer to TI00405C/07/EN. Note! For the instrument you need the "ToF Adapter FXA291" as an additional accessory.
  • Page 75: Antenna Extension Far10

    Micropilot M FMR230 PROFIBUS PA Accessories Antenna extension FAR10 8.6.1 Dimensions instrument horn material 316L/1.4404 mm (in) L00-FMRxxxxx-00-00-06-en-002 8.6.2 Ordering information: Material 316L 316L + EN10204-3.1 material, NACE MR0175 (316L wetted parts) inspection certificate 2.4600 / Alloy B2 2.4610 / Alloy C4 Special version, TSP-no.
  • Page 76: Remote Display Fhx40

    Accessories Micropilot M FMR230 PROFIBUS PA Remote display FHX40 Wall-mounting Pipe-mounting (without mounting bracket) (mounting bracket and plate supplied optionally, s. product structure) Separate housing FHX40 (IP 65) Micropilot M (4.8) Levelflex M Prosonic M O rd O rd C od...
  • Page 77: Trouble-Shooting

    Micropilot M FMR230 PROFIBUS PA Trouble-shooting Trouble-shooting Trouble-shooting instructions Micropilot M FMR 2xx -Trouble Shooting Check voltage and Not ok compare it with the Instrument does Connect the Instrument works? Ready specifications on the not respond correct voltage nameplate. Check the polarity...
  • Page 78: System Error Messages

    Trouble-shooting Micropilot M FMR230 PROFIBUS PA System error messages Code Description Possible cause Remedy A102 checksum error device has been powered off before data reset; general reset & new could be stored; avoid emc problem; calibr.required emc problem; if alarm prevails after reset,...
  • Page 79 Micropilot M FMR230 PROFIBUS PA Trouble-shooting Code Description Possible cause Remedy W611 less than 2 linearisation number of entered linearisation points < 2 correct linearisation table points for channel 1 W621 simulation ch. 1 on simulation mode is active switch off simulation mode...
  • Page 80: Application Errors

    Trouble-shooting Micropilot M FMR230 PROFIBUS PA Application errors Error Output Possible cause Remedy A warning or alarm Depending on the configuration See table of error messa- 1. See table of error messages ges (→ ä 78) (→ ä 78) has occurred →...
  • Page 81 Micropilot M FMR230 PROFIBUS PA Trouble-shooting Error Output Possible cause Remedy → If the surface is not Signal is weakened by 1. Carry out tank mapping basic calm (e.g. filling, the rough surface – the setup emptying, agitator interference echoes are 100% 2.
  • Page 82: Orientation Of The Micropilot

    Trouble-shooting Micropilot M FMR230 PROFIBUS PA Orientation of the Micropilot For orientation a marker is found on the flange or threaded boss of the Micropilot. During installation this must be oriented as follows (→ ä 10): • In tanks: to the vessel wall •...
  • Page 83 Micropilot M FMR230 PROFIBUS PA Trouble-shooting echo: highest value echo tank bottom L00-FMRxxxxx-19-00-00-en-004 Vessel empty, no interference echo false echo: smallest value false echo echo tank bottom L00-FMRxxxxx-19-00-00-en-005 Vessel empty, interference echo obtained Fix the flange or threaded boss in this position. If necessary, replace the seal.
  • Page 84: Spare Parts

    Trouble-shooting Micropilot M FMR230 PROFIBUS PA Spare Parts An overview of the spare parts for your device is available in the internet at www.endress.com. To obtain information on the spare parts, proceed as follows: Go to "www.endress.com" and select your country.
  • Page 85: Return

    Micropilot M FMR230 PROFIBUS PA Trouble-shooting Return The following procedures must be carried out before a transmitter is sent to Endress+Hauser e.g. for repair or calibration: • Remove all residue which may be present. Pay special attention to the gasket grooves and crevices where fluid may be present.
  • Page 86: Technical Data

    Technical data Micropilot M FMR230 PROFIBUS PA Technical data 10.1 Additional technical data 10.1.1 Input Measured variable The measured variable is the distance between a reference point and a reflective surface (i.e. medium surface). The level is calculated based on the tank height entered.
  • Page 87 Micropilot M FMR230 PROFIBUS PA Technical data 10.1.3 Performance characteristics Reference operating • Temperature = +20 °C ±5 °C (+68 °F ±41 °F) conditions • Pressure = 1013 mbar abs. ±20 mbar (15 psi ±0.29 psi) • Relative humidity (air) = 65 % ±20 % •...
  • Page 88 Technical data Micropilot M FMR230 PROFIBUS PA 10.1.4 Operating conditions: Environment Ambient temperature range Ambient temperature for the transmitter: -40 °C to +80 °C (-40 °F to +176 °F) or -50 °C to +80 °C (-58 °F to +176 °F). The functionality of the LCD display may be limited for temperatures Ta <...
  • Page 89 Micropilot M FMR230 PROFIBUS PA Technical data 10.1.5 Operating conditions: Process Process temperature range / Note! Process pressure limits The specific range may be reduces by the selected process condition. The pressure rating (PN) specified on the flanges refers to a reference temperature of 20 °C (68 °F), for ASME flanges to 100 °F.
  • Page 90 Technical data Micropilot M FMR230 PROFIBUS PA 10.1.6 Mechanical construction Weight • F12/T12 housing: approx 6 kg (13.32 lbs) + weight of flange • F23 housing: approx 9,4 kg (20.73 lbs) + weight of flange Material Materials of T12 and F12 housing (seawater-resistant, powder-coated)
  • Page 91 Micropilot M FMR230 PROFIBUS PA Technical data Materials of F23 housing (corrosion-resistant) F23 housing 316L (1.4404/1.4435) L00-x12xxxx-16-00-00-en-001 Pos. Part Material Housing body: 1.4404; Sensor neck: 1.4435; F23 housing earth connection block: 1.4435 Cover 1.4404 Sealing Fa. SHS: EPDM 70pW FKN...
  • Page 92 Technical data Micropilot M FMR230 PROFIBUS PA Material Ext. temperature version High temperature version 3" Tri-Clamp (in contact with process) ISO 2852 Standard antenna Antenna extension L00-FMR230xx-16-00-00-en-003 Pos. Part Material Horn antenna 316L (1.4404) Hastelloy Screw Hastelloy Spring washer Flange 316L (1.4404/1.4435)
  • Page 93 Micropilot M FMR230 PROFIBUS PA Technical data 10.1.7 Certificates and approvals CE approval The measuring system meets the legal requirements of the EC-guidelines. Endress+Hauser confirms the instrument passing the required tests by attaching the CE-mark. RF approvals R&TTE, FCC Overspill protection German WHG, see ZE00244F/00/DE.
  • Page 94 Technical data Micropilot M FMR230 PROFIBUS PA Ex approval Correlation of safety instructions (XA, XC) and certificates (ZD, ZE) to the instrument: Feature Non-hazardous area Non-hazardous area, WHG ATEX II 3G Ex nA II T6 ATEX II 1/2G Ex ia IIC T6, ATEX II 3D...
  • Page 95 Micropilot M FMR230 PROFIBUS PA Technical data 10.1.8 Supplementary Documentation Supplementary This supplementary documentation can be found on our product pages on www.endress.com Documentation • Technical Information (TI00345F/00/EN) • Operating Instructions "Description of instrument functions" (BA00221F/00/EN) • Safety Manual "Functional Safety Manual" (SD00150F/00/EN) •...
  • Page 96: Appendix

    Appendix Micropilot M FMR230 PROFIBUS PA Appendix 11.1 Operating menu PA (display modul) basic setup tank shape medium cond. process cond. empty calibr. full calibr. dome ceiling unknown standard enter value enter value horizontal cyl. DK: < 1.9 calm surface DK: 1.9 …...
  • Page 97 Micropilot M FMR230 PROFIBUS PA Appendix dist./meas.value check distance range of mapping start mapping dist./meas.value distance = ok input of D and L dist. too small mapping range are displayed D and L manual are displayed dist. unknown dist. too big safety distance in safety dist.
  • Page 98: Patents

    Appendix Micropilot M FMR230 PROFIBUS PA 11.2 Patents This product may be protected by at least one of the following patents. Further patents are pending. • US 5,387,918 i EP 0 535 196 • US 5,689,265 i EP 0 626 063 •...
  • Page 99 Micropilot M FMR230 PROFIBUS PA Appendix Endress+Hauser...
  • Page 100 Appendix Micropilot M FMR230 PROFIBUS PA Endress+Hauser...
  • Page 101: Index

    Micropilot M FMR230 PROFIBUS PA Index Index accessories ........74 level .
  • Page 102 Micropilot M FMR230 PROFIBUS PA Index trouble-shooting ....... . 77 trouble-shooting instructions .
  • Page 103 Erklärung zur Kontamination und Reinigung Please reference the Return Authorization Number (RA#), obtained from Endress+Hauser, on all paperwork and mark the RA# clearly on the outside of the box. If this procedure is not followed, it may result in the refusal of the package at our facility.
  • Page 104 www.endress.com/worldwide BA00225F/00/EN/13.11 71139431 CCS/FM+SGML 6.0 ProMoDo 71139431...