Syslog Messages Are Not Sent To The Syslog Server - Samsung WEC8500 Maintenance Manual

Wlan controller
Hide thumbs Also See for WEC8500:
Table of Contents

Advertisement

WEC8500/8050 Maintenance Manual
1.2.4

Syslog messages are not sent to the syslog server

Symptoms
The alarm and log messages generating in the APC system are not sent to the syslog server.
Possible Causes
The syslog server is not configured.
Internet Protocol (IP) address and port of the syslog server are not configured.
Alarm and log messages are not sent due to the filter settings.
Solutions
1) Check the alarm message settings. Check the alarm filter information ('Alarm Group
Filter' and 'Alarm Level filter'), and if the filter information is not setup, use the
'alarm group system' and 'alarm level major' commands to configure the following
settings.
WEC8500# show alarm conf
------------------------------------------
Alarm Log Configuration
------------------------------------------
Alarm Group Filter
Alarm Level Filter
Alarm Log File Size
Alarm Log File Count
Alarm Log STD Out
2) Check the system log message settings. Check that 'Debug Log Mode' is 'On' and
check the filter information ('Debug Log Module level filter'). If the filter information
is not configured, configure the following settings.
WEC8500# show debug log conf
---------------------------------------------
Debug Log Configuration
---------------------------------------------
Debug Log Mode
Debug Log Module Filter
Debug Log Level Filter
Debug Log File Size
Debug Log File Count
Module STD Out
Module Filter STD Out
Module Level Filter STD Out
Samsung Electronics America
all
minor
10 MBytes
1
Off
On
all
warning
10 MBytes
1
Off
all
debug
Version 5.1