WEC8500/8050 Maintenance Manual
1.6.2

Trap cannot be sent

Since all alarms of the system are sent to the outside as SNMP Trap by default, any
external management server used for receiving the system alarms must have its address
registered as a trap target.
Symptoms
No trap is sent from the APC.
Possible Causes
Not registered as a trap receiver on the APC.
The Trap server (or PC) and the APC are not connected to the network.
Solutions
1) Check the trap receiver list of the APC. If the server is not on the list, execute the
'snmp trap' command to add an SNMP trap target.
WEC8500# show snmp trap
Count TrapVersion TrapCommunityName IPAddress
+-----+-----------+-----------------+----------------------+-----+
1
Version 2
2) Execute the 'ping' command on the APC to check the network connection.
If the command fails, contact your network administrator
Samsung Electronics America
public
90.90.1.234
Version 5.1
Port
162