Component Identification
Integrated Air Control Module
D200, D200s, D60, and S20 Models
The integrated air controls include:
•
Main air slider valve (BA): turns air on and off to
the system. When closed, the valve relieves pres-
sure downstream.
•
Ram air regulator (BB): controls ram up and down
pressure and blowoff pressure.
•
Ram director valve (BC): controls ram direction.
•
Exhaust port with muffler (BD)
•
Air motor regulator (BE): Controls air pressure to
motor.
•
Air motor slider valve (BF): turns air on and off to
the air motor. When closed, the valve relieves air
trapped between it and the air motor. Push the valve
in to shutoff. Remote DataTrak: The air solenoid,
the air motor slider valve (BF), and the main air
slider valve (BA) must be open for air to flow. (See
Remote DataTrak Setup, in manual 312371)
•
Blowoff button (BG): turns air on and off to push
the platen out of an empty drum.
BG
BA
F
. 3. Integrated Air Control Module
IG
12
BF
BE
BD
BC
BB
ti10438a
Integrated Air Line Accessories
See F
. 1.
IG
•
Air line drain valve (U)
•
Air line filter (V): removes harmful dirt and mois-
ture from compressed air supply.
•
Second bleed-type air valve (W): isolates air line
accessories for servicing. Locate upstream from all
other air line accessories.
•
Air relief valve (not visible): automatically relieves
excessive pressure.
2-Button Interlock Air Controls
D200i, D200si, and D60i Models
Units that have 2-Button Interlock controls have the fol-
lowing additional components:
•
2-Button Module: See manual 312374 for informa-
tion.
•
Roller switch (CA): shuts off air supply when it
contacts the bracket actuator. Operator must push
and hold buttons to resume ram movement.
F
. 4
IG
•
Bracket actuator (CB): attaches to the platen lift
rod. When ram is near the top, actuator makes con-
tact with the roller switch.
CA
F
. 5
IG
Activation
Buttons
ti10843a1
CB
ti10846a
313527ZAD