Package Components; Integrated Air Control Module; Air Line Accessories; Fluid Line Components - Graco Xtreme 116MCN Instructions-Parts List Manual

Wall mount packages for pumping or circulating finishing materials
Table of Contents

Advertisement

Package Components

Integrated Air Control Module

Trapped air can cause the pump to cycle unexpect-
edly, which could result in serious injury from splash-
ing or moving parts. Be sure the air bleed hole on the
integrated air control module points away from the
operator.
To help prevent fluid over pressurization, do not
exceed the maximum air inlet pressure rating to the
air motor (see page 3). If you can apply more than the
maximum air input pressure to the system, install a
safety relief valve between the bleed-type master air
valve and the air motor. The safety relief valve must
be set to open if the air inlet pressure to the motor
exceeds the motor rating.
The integrated air control module (C) is included with all
packages (see 311239). It includes the following:
Bleed-type master air valve (D): required in your
system to relieve air trapped between it and the air
motor when the valve is closed. Be sure the valve is
easily accessible from the pump and located down-
stream from the air regulator
Pump air regulator (E): a locking regulator to
adjust air pressure to the motor and fluid outlet pres-
sure of pump. View the gauge (F) to read air pres-
sure.
Safety relief valve (G): automatically opens to
relieve air pressure, to prevent pump overpressur-
ization.
Air line filter (H): removes harmful contaminants
from entering the air control module and air motor.

Air Line Accessories

Install the following accessories in the order shown in
F
. 2, using adapters as necessary.
IG
Second bleed-type air valve (R): isolates air line
accessories for servicing. Locate upstream from all
other air line accessories.
312358F
Air line moisture drain valve (S): install at the bot-
tom of each air line drop, to drain moisture.

Fluid Line Components

Some Xtreme and Dura-Flo packages include fluid suc-
tion kits and fluid filter kits. See pages 13, 15, and 16.
Fluid filter (J): with a 60 mesh (250 micron) stain-
less steel element to filter particles from the fluid as
it leaves the pump.
Fluid drain valve (K): required in your system, to
relieve fluid pressure in the hose and gun.
55 Gal. (200 Liter) Suction kit (L): enables the
pump to draw fluid from a drum. Includes bung
adapter.
5 Gal. (19 Liter) Suction kit (M): enables the pump
to draw fluid from a pail.