Repair

Disconnect Pump from Platen

The pump is mounted to the platens by mounting kit
255392 or 257630. See the Repair Kits on page 64.
30 and 55 Gallon Platen
1. Remove four hex screws (426), four clamps (427),
and washers (425).
2. Carefully pull pump away to prevent damage to
pump inlet and remove o-ring (428)
428
Dura-Flo Mounting
428
F
. 18: 55 and 30 Gallon Mounting Kit
IG
313527ZAD
Check-Mate Mounting
426
425
427
TI10422A
426
425
427
312373_1
20, 30, and 60 Liter Platen
1. Loosen two 5/16 in. screws (462) from platen.
2. Carefully pull pump away to prevent damage to
pump inlet. If using a pump with intake adapter,
remove screws (472), adapter (471), and o-rings
(473, 463) from pump inlet.
Check-Mate Mounting
462
Dura-Flo Mounting
462
F
. 19: 20, 30, and 60 liter mounting kit
IG
Repair
463
r_255648_313527_35a
473
471
472
463
r_255648_313527_36a