Advanced Configuration of the XT Series
2. Set the time limit for point-to-point calls.
a. Access call settings. From the XT Series web interface, select, select Administrator
Settings > Calls > Preferences > General. From the endpoint's main menu,
selectConfigure > Advanced > Calls > General.
b. Define the time limit for point-to-point calls in the Call Time Limit field. By default, the
time limit is Unlimited. The maximum limit you can set is 24 hours.
Related links
Advanced Configuration of the XT Series

Configuring Advanced Sound (Audio Output) Settings

About this task
In most cases, the Avaya Scopia
default settings. However, for complex room setups, the XT Series allows you to carefully merge
different audio signals into audio tracks, and then route each track to any audio output, like a
monitor's speakers. Merging all inputs and outputs into one sound stream, or track, creates echos
and audio feedback loops.
Therefore the XT Series handles audio in two separate tracks. Each track can combine multiple
inputs into one sound stream, and routes it to one of the audio outputs available
Example of merging audio into two tracks
December 2017
on page 121
®
XT Series sound output is transparent and works with the
Figure 92: Echo or feedback loops to be avoided
on page 143). In the illustrated example, the room's