Telegrams For Sic/Scc Communication - Siemens SINUMERIK 840D sl Configuration Manual

Sinumerik step 7 toolbox v14 sp1
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

5.7.4

Telegrams for SIC/SCC communication

The standard telegram configuration (Page 104) of a SINUMERIK NCU with Safety
Integrated plus (F-PLC) uses the following telegram types for SIC/SCC communication:
Table 5- 6
Telegrams for control via PROFIsafe and SIC/SCC (PROFIdrive)
Profile
PROFIdrive (SIC/SCC)
For the purpose of implementing a user-defined telegram configuration (Page 110), you can
also configure telegram 700.
Further information
You will find a brief description of all configurable telegram types in the TIA Portal in the
tooltip for the telegram. Detailed information can be found in the respective function block
diagrams in the SINAMICS S120/S150 List Manual
(https://support.industry.siemens.com/cs/document/109739998/).
Telegram
700...701
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325
Designation
SIEMENS telegram 701
Configuring telegrams and drive units
Purpose
Manufacturer-specific telegram for SIC/SCC communication.
With SINUMERIK, SIC/SCC communication only takes
place via telegram 701.
Function diagram
2423
5.7 Available telegram types
123