Siemens SINUMERIK 840D sl Configuration Manual page 66

Sinumerik step 7 toolbox v14 sp1
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Programming the PLC
3.6 Upgrading the PLC basic program
3. Depending on the block number assignment in your project, select one of the following
options:
The blocks are copied to your project. A check is made for duplicate block names and the
"Conflicts during copying" dialog (Page 63) is displayed.
Note
Copy further required blocks separately (e.g. DB2 variant "ExtendAlMsg=True")
If you are using PLC basic program blocks that are not contained in the master copies
folder "840D sl Basic Program > 840D sl PLC BP", you must copy them separately:
• DB2 variant "ExtendAlMsg=True" from the master copies folder
• Different external STL sources from the master copies folder "External source files"
See: Using copy templates (Page 48)Create blocks from external sources (Page 70)
4. Select the option "Replace existing objects and move to this location" and confirm with
"OK".
5. In the project tree, right-click "Program blocks" and select the "Software (compile all
blocks)" command in the "Compile" shortcut menu.
Result
The PLC basic program has been upgraded and is currently compiled.
Now you can check the copied blocks and, if applicable, manually delete the PLC basic
program blocks that you do not require (e.g. unused axis DB, channel DB, FB or FC).
If you have unused blocks in your project, some tasks take unnecessarily long, e.g. the
loading or the creation and import of SINUMERIK archives.
66
Assignment of the PLC
GP No. range
Through blocks of other
creators
or
Exclusively through PLC
basic program blocks
Exclusively through PLC
basic program blocks
"ALMSG_DB_ExtendAlMsg"
Possible procedure
Overwriting specific PLC basic program blocks
1. Open the lower-level master copies folders and select only those
PLC basic program blocks that you use in your project.
To select successive objects, click on the first object, press
and hold the Shift key and then click on the last object.
To select non-successive objects, press and hold the Ctrl key
and click on the objects one-by-one.
2. Drag and drop the selected blocks into your "Program blocks"
folder, e.g. under "CNC_1 > PLC_1 > Program blocks".
Overwriting the PLC basic program including folder structure as a
whole
Drag and drop the entire master copies folder "840D sl PLC BP" into
your "Program blocks" folder, e.g. under "CNC_1 > PLC_1 > Program
blocks".
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017