Positioning accuracy is bad.
C a t e g o r y
S y s t e m
Position commands (amount of
command pulses) are not cor-
r e c t .
R e a d i n g o f i n - p o s i t i o n s i g n a l s
occurs at the edge.
The form and width of the com-
m a n d p u l s e s d e v i a t e f r o m t h e
specified values.
A d j u s t m e n t
T h e p o s i t i o n l o o p g a i n i s t o o
small.
Parameter
The setting of in-position detec-
tion range (Pr60) is too large.
The command pulse frequency
exceeds 500 kpps.
Wiring
CN I/F signals are chattering:
1) Servo-ON signals
2) Counter clear input
Installation
Load inertia is large.
C a u s e s
Count the number of feedback pulses on the monitor
screen of PANATERM
and forth within a fixed distance. If the number of
feedback pulses varies, adjust the controller. Take
measures to reduce the noise on the command pulse.
Use the waveform graphic screen of PANATERM
to monitor the position error when the in-position
signals are received. Read the in-position signals at
a mid point on the time span, not at the edge.
If the command pulses are deformed or narrowed,
adjust the pulse generation circuit. Take measures
to reduce the noise on the command pulse.
Check the amount of position error on the monitor
screen of PANATERM
to the extent that no oscillation occurs.
Decrease the value of Pr60 (in-position range) to the
extent that the in-position signals do not chatter.
Decrease the command pulse frequency. Change the
values of Pr46 through Pr47 (numerator of 1st to
2nd command scale).
1) Check the wiring and connections between CN I/F pins 2
2) Check the wiring and connections between CN I/F pins 4
Check the overshoot at stop using the wave form graphics
function of PANATERM
fective, increase the capacity of the amplifier and motor.
- 71 -
C o u n t e r m e a s u r e s
while repeating travel to back
"
. Increase the value of Pr10
"
and 13 by monitoring the display of input and output sig-
nals status. Modify the wiring so that Servo-ON signals
can be made active correctly. Check the controller.
and 13 by monitoring the display of input and output sig-
nals status. Modify the wiring so that the position error
counter clear input cannot be made active during op-
eration. Check the controller.
"
. Adjust the gains. If this is not ef-
"