Pin Assignment X3 Ser1 Rs232C; Pin Assignment X3 Ser2 Rs232C - Omron NT4S Operation Manual

Nt-series programmable terminal
Table of Contents

Advertisement

The Terminals of the NT-Series
1.5.4

Pin Assignment X3 SER1 RS232c

1.5.5

Pin Assignment X3 SER2 RS232c

Interface for communication with controller.
Pin
Designation
1
Shield
6
TD
15
CTS
17
RTS
18
RD
25
SGND
A shielded cable with stranding in layers (cable type LiYCY) and with a minimum
cross-section of 0.25 mm
Connect the cable shield to the metal hoods of the connectors over as large a
surface as possible!
Interface for download, upload and logging printer.
Pin
Designation
2
TD
3
RD
4
RTS
5
CTS
7
SGND
20
DTR
A shielded cable with stranding in layers (cable type LiYCY) and with a minimum
cross-section of 0.25 mm
Connect the cable shield to the metal hoods of the connectors over as large a
surface as possible!
Channel
Function
SER1
Shield
SER1
Transmit Data
SER1
Clear To Send
SER1
Request To Send
SER1
Receive Data
SER1
Signal Ground
2
must be used. The maximum cable length is 15 m.
Channel
Function
SER2
Transmit Data
SER2
Receive Data
SER2
Request to Send
SER2
Clear To Send
SER2
Signal Ground
SER2
Data Terminal Ready
2
must be used. The maximum cable length is 15 m.
Section 1-5
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nt15sNt18s

Table of Contents