2 Information Center Configuration
2.
----End

2.3.7 Outputting Alarms to the Terminal

By outputting alarms to the terminal, you can view the operating status of the device on the
terminal.
Context
Do as follows on the switch configured with the information center:
Procedure
Step 1 Configuring the alarms to be output through the channel
1.
2.
Step 2 Configuring the channel through which alarms are output to the VTY terminal
1.
2.
Step 3 Enabling terminal display
1.
2.
----End
2-22
Run:
terminal trapping
Displaying alarms on the terminal is enabled.
Run:
system-view
The system view is displayed.
Run:
info-center source { module-name | default } channel { channel-number | channel-
name } [ trap { state { off | on } | level severity } * ]
Alarms are added to the information channel.
By default, the timestamp format of alarms is date.
Run:
info-center monitor channel { channel-number | channel-name }
The channel through which alarms are output to the VTY terminal is configured.
By default, alarms are output to the VTY terminal through Channel 1.
Run:
quit
Back to the user view.
Do as follows on the switch configured with the information center, run:
terminal monitor
Terminal display is enabled.
Run:
terminal trapping
Displaying alarms on the terminal is enabled.