Preparing the Burner for Startup (continued)
6.
Initial Adjustment of the Combustion Air Band:
WARNING: The combustion air band must be properly adjusted to ensure that the burner
ignites and burns correctly. DO NOT attempt to start the burner with the combustion air band
wide open or completely closed. The burner may not ignite correctly. Failure to heed this warning may
result in a fire or explosion hazard.
Refer to Figure 6A to locate the combustion air band.
Rotate the combustion air band to adjust it to the appropriate initial slot opening as listed
in the following Initial Adjustment Charts. Use a ruler to accurately set the combustion air
band gap.
IMPORTANT NOTE: This initial setting of the combustion air band will allow you to start the burner.
You will fine tune the combustion air band further as described later in these instructions.
ATTENTION: The settings shown in the charts below are only initial adjustments. Final
adjustments must be done by inspecting the flame length according to the illustration
provided on the following page.
NOTE: The oil pressure is automatically adjusted by the metering pump.
Initial Adjustments for the Saturn™ 140 Furnace
Maximum Input = 140,000 BTUH @ 1.0 GPH with Saturn™ 125 Burner
Oil Type
#2 Fuel Oil
#4 Fuel Oil
Used Crankcase Oil
Used ATF
Used Hydraulic Oil
Initial Adjustments for the Saturn™ 230 Furnace
Maximum Input = 230,000 BTUH @ 1.6 GPH with Saturn™ 125 Burner
Oil Type
#2 Fuel Oil
#4 Fuel Oil
Used Crankcase Oil
Used ATF
Used Hydraulic Oil

Starting the Burner

1.
Turn the switch on the wall thermostat to HEAT and adjust the thermostat setting above room
temperature to start the burner.
2.
Adjusting the Air Regulator:
As soon as the burner starts running, turn the knob on the air regulator clockwise to achieve
proper operating air pressure. Refer to the Initial Adjustment Charts.
NOTE: If the safety reset on the primary control is activated and the burner stops running, see
Section 7 for further instructions on restarting your burner.
Operator's Manual: Models Saturn™ 140 & Saturn™ 230
Oil PSI / Flame Length
check flame length
check flame length
check flame length
check flame length
check flame length
Oil PSI / Flame Length
check flame length
check flame length
check flame length
check flame length
check flame length
Air PSI
14-18
14-18
14-18
14-18
14-18
Air PSI
14-18
14-18
14-18
14-18
14-18
6-2
Air Band
Nozzle
1/2"
9-5
1/2"
9-5
1/2"
9-5
1/2"
9-5
1/2"
9-5
Air Band
Nozzle
5/8"
9-5
5/8"
9-5
5/8"
9-5
5/8"
9-5
5/8"
9-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

230140

Table of Contents