Installing The Air Line Tubing; Locking The Burner Into Firing Position - Saturn 125 Operator's Manual

Multi-oil furnace saturn 125-burner
Table of Contents

Advertisement

Installing the Connector Block, Oil Line Tubing, and Air Line Tubing
(continued)

Installing the Air Line Tubing

1.
Remove and discard the red caps from the air line tubing.
2.
Push the air line tubing into the push fitting on the connector block until the tubing bottoms out in the
fitting.
3.
Repeat this procedure to connect the air line tubing to the air line fitting on the the burner.

Locking the Burner into Firing Position

1.
Swing the burner into firing position.
2.
Install and tighten the lock-down nut on the mounting plate bolt to secure the burner in its firing position.
3.
Plug the burner electrical cable into the receptacle on the top of the burner housing.
4.
Tighten the locking ring to secure the electrical cable.
NOTE: Be sure to properly align the plug when plugging it into the receptacle. See Fig 3G.
NOTE: Your furnace is now assembled and ready for installation. Install the furnace as
soon as possible so the burner and/or fan are not "bumped" or damaged. If you must
store the furnace for a period of time before installation, make sure it is located in a safe,
secure area.
Operator's Manual: Models Saturn™ 140 & Saturn™ 230
Figure 3G - Detail of Burner Electric Receptacle
CONNECTOR PLUG
KEY IN PLUG
MUST ALIGN
WITH SLOT IN
RECEPTACLE
RECEPTACLE ON
TOP OF BURNER
I88641−B