Keyword: Type-02 1b0800 1771520
Hot Swap Cage: SCSI cable removed
Logged by: BMC;
Data1: Device Removed/Device Absent
0x203E4D0AC6020220 FFFF0008F61B0300
Log Entry 73: 00:00:12
Alert Level 3: Warning
Keyword: Type-02 050301 328449
The server's built-in sensors have detected an open chassis door.
Logged by: BMC;
Data1: State Asserted
0x200000000C020570 FFFF010302050300
NOTE
Systems without a Management Processor Card
The system LED states operate the same with systems having the optional management processor card.
Table 5-3
Power and System LED States
Power LED
Off
On (green)
On (green)
On (green)
On (green)
Diagnostic LEDs
Four diagnostic LEDs are provided on the display panel of the system. Additional diagnostic LEDs are
provided on the system board and are described later in this chapter.
The diagnostic LEDs warn of impending failures or present failures and allow you to take preventive or
corrective action, such as making a system backup or replacing a component. These diagnostic LEDs are
labeled 1, 2, 3 and 4.
If no management processor card is installed, the boot progress is monitored by diagnostic LEDs 1
through 4. During the boot-up the LEDs will turn on in sequence until the EFI prompt is reached.
Chapter 5
Sensor: Cable / Interconnect - SCSI ChExt Cable
Sensor: Physical Security - Chassis Open
More detailed information on the system logs is presented in Chapter 4, "Utilities."
System LED
Off
Solid green
Blinking green
Blinking yellow (1/sec.)
Blinking red (2/sec.)
Identifying and Diagnosing Hardware Problems
State
Off
Running
Booting or running code other than
operating system (boot or
diagnostic).
Attention indication
Fault indication
Troubleshooting