Troubleshooting
Identifying and Diagnosing Hardware Problems
<CR>
Continue to the next or previous block
D
Dump the entire log for capture and analysis
F
First entry
L
Last entry
J
Jump to entry number
V
View mode configuration (text, keyword, hex)
?
Display this Help menu
Ctrl-B
Quit and return to the Main Menu
Step 4. Select a, then a threshold filter number to filter events to desired level.
MP:SL (+,-,<CR>,D, F, L, J, H, K, T, A, U, ? for Help, Q or Ctrl-B to Quit) >a
Alert Level Threshold Filter:
1
: Major Forward Progress
2
: Informational
3
: Warning
5
: Critical
7
: Fatal
Enter alert level threshold or [Q] to quit filter setup: 3
-> Alert threshold level 3 filter will be applied.
Step 5. Select v, then t to change the display to text mode:
Display Mode Configuration:
Current -> K - Keyword mode
Enter new value, or [Q] to Quit:
Step 6. To decode the blinking state of system LED, review the entire SEL and look at events with alert
level 3 and above.
For example:
Log Entry 24: 14 Feb 2003 15:27:02
Alert Level 3: Warning
88