a. Refer to "Removing and Replacing Components" in the hp Integrity rx1620 Maintenance Guide for
detailed instructions on the maintenance action.
Table 5-18
Processor Faults
System
LED 1
LED
Flashing
Red
Red
Flashing
Red
Red
Flashing
Red
Red
Table 5-19
BMC Faults
System
LED 1
LED
Flashing
Red
Red
Flashing
Red
Red
Table 5-20
Temperature Faults
System
LED 1
LED
Flashing
Red
Red
Chapter 5
LED 2
LED 3
Red
Green
Off
Red
Off
Green
Red
Green
Green
LED 2
LED 3
Green
Red
Green
Red
LED 2
LED 3
Green
Green
Identifying and Diagnosing Hardware Problems
LED 4
Problem
Processor 0
temperature
exceeds limit
Processor 1
temperature
exceeds limit
No processor
detected.
LED 4
Problem
Off
BMC
firmware is
damaged
Green
System
board FRU
inventory
device
inaccessible
LED 4
Problem
Red
External air
temperature
too high
Solution
Make sure nothing is blocking the
system's airflow and locate your
system in an air-conditioned
room. In a single CPU
configuration, verify that the
airflow blocker is installed.
Verify that the processor or
processors are correctly installed.
See "Installing and Configuring"
in the hp Integrity rx1620
Maintenance Guide for
installation procedures.
Solution
Turn off and unplug the system.
Wait 20 seconds, then plug in and
restart the system. If the error
repeats, replace the base unit.
Replace the base unit.
Solution
Make sure nothing is blocking
the system's airflow and locate
your system in an
air-conditioned room.
Troubleshooting