ZyXEL Communications P-793H v3 User Manual page 191

P-79x series g.shdsl.bis broadband gateway
Hide thumbs Also See for P-793H v3:
Table of Contents

Advertisement

Figure 118 Advanced > Remote MGMT > CWMP
The following table describes the labels in this screen.
Table 80 Advanced > Remote MGMT> CWMP
LABEL
DESCRIPTION
Enable
Select On for the P-79X to send periodic inform via TR-069 on the WAN.
Otherwise, select Off.
ACS URL
Enter the URL or IP address of the auto-configuration server.
ACS Username
Enter the TR-069 user name for authentication with the auto-configuration
server.
ACS Password
Enter the TR-069 password for authentication with the auto-configuration server.
Enable Periodic
Select On for the P-79X to send periodic inform via TR-069 on the WAN.
Inform
Otherwise, select Off.
Periodic Inform
Enter the time interval (in seconds) at which the P-79X sends information to the
Interval
auto-configuration server.
Connection
Enter the connection request user name.
Request
When the ACS makes a connection request to the P-79X, this user name is used
Username
to authenticate the ACS.
Connection
Enter the connection request password.
Request
When the ACS makes a connection request to the P-79X, this password is used to
Password
authenticate the ACS.
Apply
Click this to save your changes.
Cancel
Click this to restore your previously saved settings.
Chapter 19 Remote Management
P-79X Series User's Guide