Network > [1] Ethernet > (Choose The Bus Module Or On-Board) > [3] Dns; Network > [2] Cellular > (Choose The Sdi2 Cellular Module Or Plug-In Module) - Bosch B6512 Installation Manual

Hide thumbs Also See for B6512:
Table of Contents

Advertisement

106 en | Keypad Installer menu
20.1.7
[2] Network > [1] Ethernet > (choose the bus module or on-board) > [3]
DNS Parameters menu
IPv4 Server Address
1.
2.
3.
4.
5.
6.
IPv6 Server Address
1.
2.
3.
4.
5.
6.
Module Hostname
1.
2.
3.
4.
5.
6.
20.1.8
[2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in
module)
You can use a B44x cellular communication module for communication. Plug it directly into the
control panel or use it with a B450 module.
Access Point Name
Access Pt Username
Access Pt Passcode
SIM PIN
2017.04 | 15 | F.01U.287.180
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [3] DNS Parameters > [1] IPv4 Server Addr. The keypad shows the IPv4
Server Address current configuration.
Press Edit or Enter to edit the IPv4 Server Address.
Delete the existing number, if necessary, and then enter the new number. Use
Previous or
/Next to move to a different byte.
Press Save or Enter. The keypad shows Parameter saved.
Escape from the menu.
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [3] DNS Parameters > [2] IPv6 Server Addr. The keypad shows the IPv6
Server Address current configuration.
Press Edit or Enter to edit the IPv6 Server Address.
Delete the existing number, if necessary, and then enter the new number. Use
Previous or
/Next to move to a different byte.
Press Save or Enter. The keypad shows Parameter saved.
Escape from the menu.
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [3] DNS Parameters > [3] Module Hostname. The keypad shows the current
hostname.
Press Edit or Enter to edit the hostname.
Delete the existing number, if necessary, and then enter the new number. Use
Previous or
/Next to move to a different byte.
Press Save or Enter. The keypad shows Parameter saved.
Escape from the menu.
Module 1 settings
_______________________________
_______________________________
_______________________________
_______________________________
Installation Manual
Control Panels
Module 2 settings
_______________________________
_______________________________
_______________________________
_______________________________
Bosch Security Systems, Inc.
/
/
/

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B5512B4512B3512B5512eB4512eB3512e

Table of Contents