64
en | Wireless modules
Caution!
Remove all power (AC and battery) before making any connections. Failure to do so might
!
result in personal injury and/or equipment damage.
Install the module
1.
2.
3.
4.
Wire to the control panel
When wiring a module to a control panel, use the terminal strip labeled with PWR, A, B, and
COM to wire to the SDI2 terminals labeled on the control panel. For terminal wiring, use 18
AWG to 22 AWG (1.02 mm to 0.65 mm) wire. Do not exceed a wire length of 1000 ft (300 m)
from the control panel.
Route the cabling through the control panel enclosure, and through the EN4200 housing.
3
Figure 14.2: B820 to control panel wiring (B5512 shown)
Callout ᅳ Description
1 ᅳ Control panel
2 ᅳ Module
3 ᅳ Terminal strip wiring
2017.04 | 15 | F.01U.287.180
Set the module address using the address switch before you install it in the EN4200
housing.
Use a slotted screwdriver top press the housing release tabs and open the housing.
Remove the backing from the Velcro piece found in the product packaging to reveal the
Velcro adhesive. Place the Velcro's adhesive side onto the back of the module. Remove
the remaining backing to use to secure the module in the housing.
Insert the module into the house, connect the serial ports on the B820 and EN4200, and
then press gently.
Refer to the EN4200 EchoStream Serial Receiver Installation Instructions for mounting and
wiring instructions for the receiver.
1
SDI2
ON-BOARD POINTS
Device Bus
Voltage Ranges
R Y G B
Open
3.7 - 5.0 VDC
Normal
2.0 - 3.0 VDC
Short
0.0 - 1.3 VDC
1 k
End of Line Resistors
AUX
1 COM 2
3 COM 4 5 COM 6
- 12 V +
COM AUX
R
Y
G
B
1
COM
2
3
COM
4
5
COM
PWR A
B COM
R
Y
G
B
C
OUTPUT
B
7 COM 8
6
7
COM
8
Installation Manual
2
Bosch Security Systems, Inc.
Control Panels

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B5512B4512B3512B5512eB4512eB3512e

Table of Contents